UNI-T A56 BT Bluetooth Temperature and Humidity Datalogger IP54
€41.17
Currently not available (delivery time on request)
| Product number: | 202717 |
|---|---|
| Manufacturer number: | A56 BT |
| EAN | 6935750556030 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T A56 BT Bluetooth Temperature and Humidity Datalogger IP54"
Main Product Features
- Temperature measurement range: -40°C to +85°C (-40°F to 185°F) with ±0.3°C accuracy between 0°C and 60°C
- Relative humidity measurement range: 0% to 100% RH with ±2.5% RH accuracy (at 25°C, 0% to 90% RH)
- Data storage capacity: 64,000 sets of measurement data
- Adjustable recording interval: 10 seconds to 24 hours via app or PC software
- Dual connectivity: Bluetooth interface for the TempLink mobile app and USB Type-C interface for PC software
- Visual and audible notification: LED indicators and built-in buzzer alarm for configurable threshold violations
- Enclosure protection rating: IP54 rating against dust and water spray
- Flexible installation: Integrated rear magnets and mounting holes for wall attachment
Environmental Tracking in Cold Chain and Storage
The UNI-T A56 BT is built for continuous recording of ambient temperature and relative humidity across commercial facilities. It covers temperatures from -40 °C to +85 °C alongside complete humidity spans, making it suitable for cold-chain logistics, pharmaceutical cabinets, supermarket refrigeration, and warehouse monitoring. An IP54-rated housing provides ingress protection against dust and water spray.
Data Logging and Configurable Alarms
Up to 64,000 data points can be stored in the internal memory at intervals adjustable from 10 seconds to 24 hours. The backlit screen shows real-time readings, time, battery level, and calculated MIN, MAX, and AVG values. When ambient parameters exceed user-defined thresholds, the logger triggers visual warnings via LED indicators and acoustic signals via an internal buzzer.
Data Transfer and Installation Options
Log files can be collected wirelessly via Bluetooth using the TempLink app on Android and iOS devices, or retrieved through the USB-C port using PC software. The software suite provides graphical trend analysis and automated report generation in PDF and CSV formats. For mechanical placement, the unit features built-in rear magnets for metal surfaces as well as integrated wall-mounting holes.
| Temperature Measurement Range | -40°C to +85°C (-40°F to 185°F) |
| Temperature Accuracy | ±0.3°C (0°C to 60°C), ±0.5°C (-40°C to 0°C & 60°C to 85°C) |
| Humidity Measurement Range | 0% to 100% RH |
| Humidity Accuracy | ±2.5% RH (at 25°C, 0% to 90% RH), ±3.5% RH (at 25°C, 90% to 100% RH) |
| Resolution | 0.1°C (0.1°F) / 0.1% RH |
| Data Storage Capacity | 64,000 sets |
| Recording Interval | 10 s to 24 h (configurable via PC / App) |
| Connectivity Interfaces | Bluetooth, USB Type-C |
| Operating Temperature & Humidity | -40°C to +85°C, ≤99% RH |
| Ingress Protection Rating | IP54 |
| Power Supply | 1x 3.6V Li-SOCl2 Battery ER14505 (2700 mAh) |
| Battery Operating Life | Up to 2 years (room temperature, 15 min interval, 15 s screen off, buzzer off, indicators/backlight/Bluetooth off) |
| Dimensions | 104 x 62 x 25 mm |
| Net Weight | approx. 110 g (with battery) |
Frequently Asked Questions
Which software applications work with the UNI-T A56 BT?
The datalogger connects to mobile devices via the TempLink app (compatible with Android and iOS) and can be evaluated on computers using the dedicated UNI-T PC software.
Can the datalogger be started without a computer or smartphone?
Yes, recording runs can be started and stopped manually using the push buttons on the front panel, while alarm thresholds and log intervals must be preconfigured via the app or PC software.
What data formats can be exported from the software?
The companion PC software and application support automatic report generation and data export in PDF and CSV file formats.
Is the internal memory cleared automatically or manually?
Memory is reset manually using the PC software or the mobile app after data backup, preparing the device for a new logging session.
Is the battery replaceable?
Yes, the datalogger is powered by a standard 3.6V ER14505 Li-SOCl2 lithium battery that can be replaced by the user.
| Product number: | 202717 |
|---|
| Flyer: | A56BT Datenblatt Data Sheet.pdf |
|---|---|
| Manual: | A56 BT Anleitung Deutsch.pdf |
| Other documents: | A56 BT User Manual English.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.