UNI-T UT206C Digital Clamp Meter True RMS 1000A AC VFD
€46.21
Available, delivery time: 1-3 days
| Product number: | 202734 |
|---|---|
| Manufacturer number: | UT206C |
| EAN | 6935750521830 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UT206C Digital Clamp Meter True RMS 1000A AC VFD"
Main Product Features
- High-Current AC Measurement: Accurately measures alternating current up to 1000A without breaking the circuit.
- True RMS & 6000-Count Display: Delivers precise readings on distorted or non-sinusoidal waveforms with a clear, backlit LCD.
- Specialised VFD Mode: Filters interference for reliable voltage and frequency analysis on variable frequency drives and inverters.
- Ultra-Slim & Compact Design: Features a thin 10mm jaw profile, a 33mm jaw opening, and an overall weight of only approx. 130g.
- Automatic Component Identification: Intelligently detects resistance, continuity, and diode testing modes.
- Comprehensive Testing Ranges: Measures AC/DC voltage up to 600V, capacitance up to 10.00mF, and frequency up to 100kHz.
Professional Electrical Diagnostics with the UNI-T UT206C
The UNI-T UT206C sets a new standard for portable diagnostic tools by combining the power of a heavy-duty 1000A AC ammeter with the lightweight convenience of a pocket-sized multimeter. Weighing around 130 grams and measuring merely 190 x 68 x 20 mm, this device fits comfortably in any tool pouch or pocket, ensuring technicians and electricians always have reliable diagnostic capability close at hand. Designed for demanding commercial, residential, and facility maintenance environments, it simplifies troubleshooting while delivering uncompromised precision.
VFD Mode for Modern Motor Drives and Inverters
Modern electrical installations increasingly rely on pulse-width modulated (PWM) signals, variable frequency drives (VFDs), and solar inverters. Traditional averaging meters often fail to capture accurate measurements in these electrically noisy environments. The UT206C incorporates a dedicated VFD measurement mode designed to filter high-frequency carrier interference, enabling stable and repeatable readings of both output voltage and frequency. Combined with True RMS processing, it ensures dependable diagnostics whether you are balancing three-phase motor loads or servicing industrial ventilation units.
Ultra-Thin Jaw Profile for Crowded Distribution Panels
One of the primary frustrations when servicing modern distribution boards is tight cable spacing. The UT206C addresses this challenge directly with an ultra-thin 10mm jaw profile and a generous 33mm conductor aperture. Technicians can easily route the clamp around thick cables or densely packed wiring without dislodging adjacent conductors. Functions like automatic identification for resistance, continuity, and diodes streamline workflow by eliminating manual dial switching during routine circuit checks.
Certified Safety and Full EU Compliance
Safety is paramount during live testing. The UNI-T UT206C is engineered to adhere to stringent international standards, carrying CAT III 300V and CAT II 600V overvoltage category ratings. It has undergone extensive conformity assessments, achieving both CE and cETLus certifications. This assures European trade professionals that the instrument satisfies all essential EU safety, health, and environmental protection requirements. Integrated overload protection, a Data Hold function, bright LCD backlighting, and auto-power-off ensure risk-mitigated operation even in dimly lit switchboards.
Technical Specifications
| Parameter | Measurement Range | Resolution | Accuracy |
|---|---|---|---|
| AC Current (A) | 60.00A / 600.0A / 1000A | 0.01A / 0.1A / 1A | ±(2.0%+10) / ±(2.0%+5) |
| ACA Frequency (Hz) | 45Hz – 400Hz | 0.01Hz – 0.1Hz | ±(0.1%+3) |
| AC Voltage (V) | 6.000V / 60.00V / 600.0V | 0.001V / 0.01V / 0.1V | ±(1.2%+5) |
| VFD Voltage (AC) | 600.0V | 0.1V | ±(8%) |
| ACV Frequency (Hz) | 10Hz – 100kHz | 0.01Hz – 0.1kHz | ±(0.1%+3) |
| DC Voltage (V) | 6.000V / 60.00V / 600.0V | 0.001V / 0.01V / 0.1V | ±(1.0%+2) |
| Resistance (Ω) | 600.0Ω / 6.000kΩ / 60.00kΩ / 600.0kΩ / 1.000MΩ | 0.1Ω / 0.001kΩ / 0.01kΩ / 0.1kΩ / 0.001MΩ | ±(1.0%+5) / ±(1.0%+2) |
| Capacitance (F) | 6.000μF / 60.00μF / 600.0μF / 6.00mF / 10.00mF | 0.001μF / 0.01μF / 0.1μF / 0.01mF / 0.01mF | ±(2%+5) / ±(5%+5) / ±(10%) |
| Display Count | 6000 counts | – | – |
| Jaw Capacity & Thickness | 33mm opening / 10mm thickness | – | – |
| Safety Ratings | CAT III 300V / CAT II 600V, CE, cETLus | – | – |
| Power Supply | 2x 1.5V AAA batteries | – | – |
| Dimensions & Weight | 190 x 68 x 20 mm / Approx. 130g | – | – |
Frequently Asked Questions (FAQ)
Can the UT206C measure DC current via the clamp?
No, the clamp jaw on the UT206C is engineered exclusively for AC current measurements up to 1000A. However, DC voltage can be measured up to 600V using the included test leads.
What is the benefit of the VFD function?
The VFD (Variable Frequency Drive) mode incorporates low-pass filtering to isolate fundamental frequencies and voltages, preventing high-frequency noise from distorting readings on inverter-driven compressors, motors, and pump drives.
Does the device come with everything required to start testing?
Yes. The standard package includes the UNI-T UT206C clamp meter, a set of test probes, two 1.5V AAA batteries, a protective cloth carrying bag, and an operating manual.
How does the automatic identification feature work?
When testing components, the UT206C can automatically discern between resistance, continuity, and diode functions, eliminating the need to manually cycle through rotary dial options during quick inspections.
Is this meter suitable for European commercial work?
Yes. The UT206C conforms strictly to relevant European safety harmonisation directives (CE compliance) and provides CAT III 300V / CAT II 600V transient protection for commercial, residential, and facility maintenance tasks.
| Product number: | 202734 |
|---|
| Flyer: | UT206C-Datasheet.pdf?ts=1789581193 |
|---|---|
| Manual: | UT206C%20Multilingual%20Manual.pdf?ts=1789581222 |
| Other documents: | UT206C%20Anleitung.pdf?ts=1789581253 |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.