UNI-T UT210E Mini Digital Clamp Meter True RMS AC/DC 100A
| Quantity | Unit price |
|---|---|
| To 9 |
€48.00
|
| To 24 |
€47.00
|
| To 49 |
€45.00
|
| From 50 |
€42.50
|
Available, delivery time: 1-3 days
| Product number: | 200373 |
|---|---|
| Manufacturer number: | UT210E |
| EAN | 6935750521052 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UT210E Mini Digital Clamp Meter True RMS AC/DC 100A"
Main Product Features
- True RMS measurement for accurate AC voltage and current readings on non-linear loads
- Measures AC and DC current up to 100A with dedicated ZERO mode for DC zeroing
- AC/DC voltage measurement up to 600V, resistance up to 20MΩ, and capacitance up to 20mF
- VFC (Variable Frequency Control) low-pass filter for stable testing of variable frequency drives
- NCV (Non-Contact Voltage) detection for quick and safe electrical live-wire verification
- Compact 17mm jaw opening tailored for crowded breaker boxes, vehicle wiring, and tight spaces
- Backlit 2000-count LCD display with data hold function and fast sampling rate of 2 to 3 times/s
- Diode test, continuity buzzer, auto power off, and low battery indication for efficient workflow
Compact Precision for Demanding Diagnostic Work
When working in modern electrical environments, tight control cabinets, compact distribution boards, and congested vehicle harnesses present unique diagnostic challenges. Standard clamp meters are often too bulky to isolate a single conductor, leaving technicians struggling to take dependable measurements. The UNI-T UT210E Mini Digital Clamp Meter solves this problem by integrating professional-grade diagnostic capabilities into an ultra-compact, ergonomic housing weighing only 170 grams.
Featuring True RMS measurement, the UT210E guarantees accurate readings even when dealing with distorted AC waveforms generated by modern power electronics, switched-mode power supplies, and LED ballasts. Its specialised 17mm jaw opening easily slips between densely packed wires, making it an indispensable diagnostic instrument for electricians, HVAC specialists, field service engineers, and automotive technicians alike.
Advanced Electronics: DC Current & VFC Low-Pass Filter
Unlike standard entry-level clamp meters that only detect alternating current, the UT210E provides high-precision AC and DC current measurement up to 100A. A dedicated ZERO mode allows you to null out residual magnetic fields with a single push of a button before taking critical DC measurements—ideal for tracing parasitic battery drains in automotive systems, inspecting solar inverter outputs, or checking low-voltage DC industrial control circuits.
Equipped with a built-in VFC (Variable Frequency Control) low-pass filter, the UT210E filters out high-frequency interference, enabling accurate and steady voltage measurements on variable frequency motor drives (VFD) and noisy electrical equipment. Combined with continuity testing, diode testing, resistance tracking up to 20MΩ, and capacitance analysis up to 20mF, it delivers the diagnostic range of a full-sized bench meter in a handheld tool.
Certified Safety and Compliance with European Standards
Safety is non-negotiable when working around live electrical panels. The UNI-T UT210E has been engineered and certified to meet stringent European safety standards. Bearing full CE conformity, it complies with CAT II 600V and CAT III 300V safety overvoltage ratings, providing verified protection against voltage transients in building installations and mains-connected equipment. The integrated Non-Contact Voltage (NCV) sensor allows users to verify live cables and sockets instantly without physical metal contact, adding an essential layer of personal protection before beginning any maintenance procedure.
| Parameter | Measurement Range | Accuracy |
|---|---|---|
| AC Current | 100A | ±(2.5% + 5) |
| DC Current | 100A | ±(2% + 3) |
| AC Voltage | 600V | ±(1% + 3) |
| DC Voltage | 600V | ±(0.7% + 3) |
| Resistance | 20MΩ | ±(1% + 2) |
| Capacitance | 20mF | ±(4% + 5) |
| Jaw Opening | 17mm | — |
| Display Counts | 2000 counts | — |
| Sampling Rate | 2 to 3 times per second | — |
| Diode Test | Around 3.0V | — |
| Continuity Buzzer | Integrated acoustic signal | — |
| Safety Rating | CAT II 600V / CAT III 300V (CE) | — |
| Power Supply | 2x 1.5V AAA (R03) Batteries | — |
| Dimensions & Weight | 175mm x 60mm x 33.5mm; 170g | — |
Frequently Asked Questions
Can the UNI-T UT210E measure DC current with the clamp jaw?
Yes, the UT210E measures both DC and AC current directly through its clamp jaw up to 100A. It also features a dedicated ZERO mode button to zero out ambient magnetic fields before taking precision DC current measurements.
What is the benefit of the VFC function?
The VFC (Variable Frequency Control) mode activates an internal low-pass filter that suppresses high-frequency noise and harmonics. This enables reliable, stable voltage readings on frequency-controlled devices such as variable speed motor drives and inverters.
Is this clamp meter safe for European domestic and commercial installations?
Yes. The UT210E meets all relevant European safety norms and carries official CE certification. It is rated for CAT II 600V and CAT III 300V environments, ensuring comprehensive user safety during mains installation and troubleshooting tasks.
What accessories are included in the package?
The package contains the UNI-T UT210E Mini Clamp Meter, a pair of premium test leads, a practical carrying bag for storage and transport, 1.5V batteries, and an English user manual.
| Product number: | 200373 |
|---|---|
| Size: | 175mm x 60mm x 33.5mm |
| Weight: | 0.12kg |
| Flyer: | 20181224102153668.pdf |
|---|---|
| Manual: | UT210E-English-Manual.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.