UNI-T UT276A+ Clamp Earth Ground Tester with 0.001Ω Resolution
€294.30
Available, delivery time: 1-3 days
| Product number: | 202693 |
|---|---|
| Manufacturer number: | UT276A+ |
| EAN | 6935750527627 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UT276A+ Clamp Earth Ground Tester with 0.001Ω Resolution"
Main Product Features
- Measures ground resistance from 0.01 Ω up to 500 Ω without disconnecting ground lines
- Resolution of down to 0.001 Ω in the lowest measuring range
- Automatic recognition and blocking of interference signals
- Integrated data storage for up to 300 measurement records with data recall
- Adjustable visual and audible resistance limit alarms
- 4-digit backlit EBTN display measuring 47 mm x 28.5 mm
- 32 mm clamp jaw opening accommodating standard grounding conductors
- Integrated auto range, auto calibration, data hold, and auto power off
- Rated according to measurement category CAT III 300V
Loop Resistance Testing Without Ground Disconnection
The UNI-T UT276A+ clamp earth ground tester is designed for electrical engineers, technicians, and maintenance professionals inspecting grounding installations, power distribution systems, and lightning protection networks. The instrument measures loop resistances between 0.01 Ω and 500 Ω without opening ground leads or placing auxiliary grounding rods into the soil, keeping installations fully operational during safety checks.
Conductor Clamping and Interference Signal Rejection
With its 32 mm jaw aperture, the clamp fits standard round conductors and ground busbars. The internal circuitry features automatic ranging and startup auto-calibration, resolving measurements down to 0.001 Ω in the lowest band. Built-in interference recognition flags external noise and electromagnetic disturbances to help prevent distorted readings in busy electrical environments.
Readout Handling, Internal Memory, and Threshold Warnings
Measurement data is presented on a 4-digit EBTN display featuring a high-contrast dark background and backlighting for dark distribution enclosures. Operators can freeze values on screen with the data-hold key and configure upper resistance limits that trigger both an acoustic beeper and an optical screen alert when exceeded. An on-board memory stores up to 300 data sets for direct on-site review using the recall function, while an automatic power-off routine helps conserve battery power during work breaks.
| Parameter | Specification |
| Model | UNI-T UT276A+ |
| Resistance Measurement Range | 0.01 Ω – 500 Ω |
| Resistance Accuracy 0.01–0.099 Ω | ±(1% + 0.01 Ω) |
| Resistance Accuracy 0.1–0.99 Ω | ±(1% + 0.01 Ω) |
| Resistance Accuracy 1–49.9 Ω | ±(1% + 0.1 Ω) |
| Resistance Accuracy 50–99.5 Ω | ±(1.5% + 0.5 Ω) |
| Resistance Accuracy 100–199 Ω | ±(2% + 1 Ω) |
| Resistance Accuracy 200–395 Ω | ±(5% + 5 Ω) |
| Resistance Accuracy 400–590 Ω | ±(10% + 10 Ω) |
| Display Type | 4-digit EBTN LCD (47 mm x 28.5 mm) |
| Jaw Opening | 32 mm |
| Data Storage Capacity | 300 records |
| Alarm | Audible and visual (resistance limit) |
| Safety Rating | CAT III 300V |
| Power Supply | 4x 1.5 V AA batteries (LR6) |
| Device Dimensions | 285 mm x 85 mm x 56 mm |
| Device Net Weight | 1.18 kg |
FAQ
Does the electrical installation need to be turned off during measurement?
No, the clamp design measures the ground loop resistance without requiring disconnection of the circuit ground lines or shutting down equipment.
Are auxiliary earth stakes or test leads required for the measurement?
No, the UT276A+ measures loop resistance directly around the conductor through the clamp mechanism without auxiliary ground stakes.
How is the functional accuracy verified on site?
A dedicated test ring is included in the scope of delivery to perform functional verification checks directly prior to testing.
How many values can be saved on the instrument?
The instrument has internal memory to store up to 300 individual data sets, which can be reviewed on screen via the Data Recall function.
| Product number: | 202693 |
|---|
| Flyer: | ut276a+-datasheet-datenblatt.pdf |
|---|---|
| Manual: | ut276a+-ut278a+-anleitung-deutsch.pdf |
| Other documents: | ut276a+-ut278a+-user-manual-english.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.