Main Produkt-Features
- Extreme Measurement Range: from -50°C to +2200°C for the most versatile industrial and trade applications.
- High Precision: thanks to the professional 55:1 distance-to-spot (D:S) ratio for accurate measurements even from a great and safe distance.
- Versatile Measurement Modes: including infrared professional mode, dew point detection, surface heat conduction detection, and temperature comparison.
- Comprehensive Data Acquisition: with internal memory for 999 readings and easy data export as PDF or CSV via the USB-C interface.
- Long-lasting Battery: allows for over 20 hours of continuous operation and is quickly ready for use again thanks to the rechargeable Li-ion battery.
- Additional Sensors: accurately measures ambient temperature, relative humidity, and supports external Type K thermocouples for contact measurements.
- Clear Color Display: The high-resolution 2.4-inch TFT color LCD clearly and legibly displays all measured values and settings.
Precision Meets Versatility: The UNI-T UT305C+ Infrared Thermometer
When it comes to exact temperature measurements in demanding environments, the UNI-T UT305C+ sets new standards. This professional infrared thermometer is designed for experts who accept no compromises on accuracy, reliability, and functionality. Whether in heavy industry, HVAC maintenance, or quality control, the UT305C+ provides the data you need to make informed decisions.
Engineered for the Most Demanding Measurement Tasks
Imagine needing to measure the temperature of a furnace, a remote power line, or a rotating machine part. With the UT305C+, this is no problem. Thanks to its impressive measurement range from -50°C to an extreme +2200°C and the high distance-to-spot ratio of 55:1, you can perform precise measurements from a safe distance. This protects not only you but also your equipment. The measurement results are displayed with crystal clarity on the brilliant 2.4-inch TFT color display.
More Than Just a Thermometer
The UT305C+ is a multifunctional diagnostic tool. In addition to pure infrared measurement, it offers special modes for detecting thermal bridges, determining the dew point to prevent mold growth, and measuring ambient temperature and relative humidity. The ability to connect an external Type K thermocouple probe extends its functionality to include precise contact measurements. You can be confident that the UT305C+ is not only precise but also completely safe and complies with all relevant EU standards (CE certified), ensuring worry-free use in a professional setting.
Data Management Made Easy
Forget pen and paper. The UT305C+ stores up to 999 readings directly in the device. For further analysis and documentation, you can easily transfer the stored data to your computer as a PDF or CSV file via the modern USB-C interface. The trigger lock function also allows for convenient continuous measurements without having to hold down the trigger.
Detailed Technical Data
| Feature | Specification |
|---|---|
| Infrared Temperature Measurement Range | -50°C to 2200°C (-58°F to 3992°F) |
| Accuracy (Infrared) | ±1.0℃ or ±1.0% of reading (whichever is greater) |
| Distance-to-Spot Ratio (D:S) | 55:1 |
| Emissivity | 0.1 to 1.0 (adjustable) |
| Ambient Temperature Measurement | -10°C to 50°C (14°F to 122°F) |
| Relative Humidity Measurement | 10%RH to 90%RH |
| Type K Thermocouple Measurement Range | -50°C to 1370°C (-58°F to 2498°F) |
| Display | 2.4 inch TFT LCD (320 x 240 pixels) |
| Data Storage | 999 groups |
| Data Output | PDF, CSV via USB-C interface |
| Laser | Single point, Class II, <1mW |
| Battery | Li-ion 3.7V 2600mAh 18650 (rechargeable) |
| Operating Time | Not less than 20 hours |
| Drop Test | 1 meter |
| Dimensions | 205 mm x 65 mm x 124 mm |
| Weight | 375 g |
Frequently Asked Questions (FAQ)
Q: Can I transfer the measurement data directly to a PC?
A: Yes, the UT305C+ has a USB-C interface that allows you to export up to 999 stored readings as a PDF or CSV file. This greatly simplifies documentation and analysis.
Q: Is the device suitable for professional use in harsh industrial environments?
A: Absolutely. With its rugged housing that withstands a 1-meter drop, wide temperature range, and professional measurement modes, it is ideally designed for demanding use in industry and trades.
Q: How long does the battery last with continuous use?
A: The powerful 2600mAh lithium-ion battery allows for a continuous working time of at least 20 hours. It can be conveniently recharged via the USB-C interface.
Q: What is included in the package?
A: The standard package includes the UT305C+ thermometer, a USB-C data cable, a Type K thermocouple probe (bead type), an instruction manual, a warranty card, and a practical tool box for safe storage.
| Product number: | 202731 |
|---|
| Flyer: | ut305c+-datenblatt-datasheet.pdf |
|---|---|
| Other documents: | ut305a+-ut305c+-user-manual-english.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.