Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UT320T 2-in-1 Thermometer | Infrared & Probe | -40°C to 300°C

€32.76*

Available, delivery time: 1-3 days

Product number: 202712
Manufacturer number: UT320T
EAN 6935750532409

Are you a reseller, need a large quantity or have a price target? 

Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via  info@schwick.de  or +49 2191 598 280

Main Product-Features

  • 2-in-1 Measurement: Combines non-contact infrared surface measurement and precise contact measurement with an NTC probe.
  • High Accuracy: Delivers reliable and exact temperature readings for professional applications.
  • 180° Collapsible Probe: The sturdy probe can be folded 180° for easy transport and safe storage.
  • Advanced Functions: MAX/MIN value display and difference measurement (T1-T2) for comprehensive analysis.
  • Adjustable Emissivity: The emissivity can be adjusted from 0.1 to 1.0 to maximize measurement accuracy on different materials.
  • Clear LCD Display: The backlit FSTN display ensures excellent readability even in poor lighting conditions.
  • Extremely Robust: IP54 rated against dust and splashing water, and withstands drops from up to 2 meters.
  • Compact Design: Fits comfortably in your hand and in any tool bag.

Two Measurement Methods, One Device: The UNI-T UT320T

The Revolution for Your Temperature Measurements

Imagine you need to check the surface temperature of an air conditioner and immediately after, measure the core temperature of a liquid. Until now, this meant two different devices, more effort, and more space in your toolbox. The UNI-T UT320T puts an end to that. This innovative 2-in-1 thermometer combines the speed of an infrared gun with the precision of a contact thermometer. Aim the device at an object to get an instant non-contact surface reading. Then, unfold the integrated probe to determine exact internal or core temperatures. Efficiency and precision in one compact tool.

Built for the Tough Workday

In the workshop, on the construction site, or in an industrial plant – your measuring device has to endure a lot. The UT320T was designed for exactly that. With its IP54 certification, it is protected against dust and splashing water. An accidental drop? No problem. The robust housing is tested for a drop height of up to 2 meters. The 180° collapsible probe is not only practical but also safely stowed when not in use. Your safety and the product's durability were paramount in the development of this device. Of course, the UT320T is CE compliant and meets all strict EU standards, so you can rely on safe and dependable measurement results.

FeatureSpecification
General Characteristics
ModelUT320T
LCD Size / Type18 x 28 mm / FSTN
Battery Type2 x 1.5V AAA
Product Size155 x 42 x 22.5 mm
Product WeightApprox. 110g (with batteries)
IP RatingIP54
Drop Test2 meters
Auto Power Off10 minutes
FunctionsData Hold, Lock Measurement, °C/°F Conversion, Max/Min/Difference
Infrared Measurement
Measuring Range-40℃ to 300℃ (-40℉ to 572℉)
Accuracy-40℃ to 0℃: ±(1.5+0.1×|t|)℃; 0℃ to 300℃: ±2.0℃ or ±2% of reading
Distance-to-Spot Ratio (D:S)8:1
EmissivityAdjustable (0.1 to 1.0)
Spectral Range5μm to 14μm
Response Time≤500ms (95% of reading)
LaserClass 2, single laser, <1mW, 650±20nm
Probe Measurement
Measuring Range-40℃ to 300℃ (-40℉ to 572℉)
Accuracy-40℃ to <0℃: ±2.0℃; 0℃ to 300℃: ±1.0℃ or ±1% of reading
Probe TypeNTC
Minimum Measuring Depth12.7 mm
Operating Conditions
Operating Temperature0℃ to 50℃ (32℉ to 122℉)
Storage Temperature-20℃ to 60℃ (-4℉ to 140℉)
Operating Humidity<90%RH (non-condensing)
Highest Operating Altitude2000 m

Frequently Asked Questions (FAQ)

What is the main advantage of the UT320T?

The biggest advantage is the combination of two measurement methods in one device. You can quickly scan surfaces with infrared and, if needed, immediately switch to a high-precision probe measurement for core or liquid temperatures without changing tools.

Is the device suitable for the food industry?

Yes, the NTC insertion probe is excellent for measuring the core temperature of food. Always observe the applicable hygiene regulations when doing so.

Can I adjust the emissivity for the IR measurement?

Yes, the emissivity is freely adjustable from 0.1 to 1.0. This allows for precise measurements on a variety of surfaces, from matte black to shiny metallic.

How rugged is the thermometer?

The UT320T is very robust. It is IP54 rated against dust and splashing water and has been successfully tested for drops from 2 meters, making it ideal for demanding work environments.

Technical data
Product number: 202712

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.