UNI-T UT363S Digital Split-Type Vane Anemometer
€26.04
Available, delivery time: 1-3 days
| Product number: | 202741 |
|---|---|
| Manufacturer number: | UT363S |
| EAN | 6935750536339 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UT363S Digital Split-Type Vane Anemometer"
Main Product Features
- Split-type design with remote vane probe for flexible measurements in hard-to-reach areas
- Dual measurement of wind speed (0.4 to 30 m/s) and ambient air temperature (-10 to 50°C)
- Comprehensive unit switching: m/s, km/h, ft/min, knots, mph, plus °C and °F
- Integrated Beaufort wind scale display from scale 0 to 12
- Multi-mode analysis with MAX, MIN, and AVG recording functions
- Data hold feature to freeze readings conveniently on the display
- Clear 35 x 32 mm backlit LCD screen for optimal visibility in dim environments
- Fast sampling rate of 0.5 seconds (2 readings per second)
- Energy-saving auto power off, overload display, and low battery indicator
- Drop-tested to 1 metre for dependable durability in industrial environments
Professional Airflow & Ventilation Monitoring
The UNI-T UT363S is an advanced digital split-type vane anemometer engineered for technicians, facility managers, and safety engineers who demand precision and ergonomics. Thanks to its detached sensor probe connected via a flexible cable, measuring airflow inside ventilation ducts, exhaust shafts, or overhead grilles becomes effortless while keeping the main backlit display right in your line of sight. It eliminates the awkward neck-craning and guesswork associated with standard handheld meters.
Versatile Across Multiple Industries
Designed for multi-sector utility, the UT363S excels in HVAC balancing, fan manufacturing, exhaust ventilation inspection, and energy conservation audits. It is equally reliable in challenging heavy industries such as mining, petrochemical facilities, iron and steel plants, as well as marine navigation, meteorology, and outdoor sports. Whether verifying airflow in commercial kitchen hoods or monitoring outdoor breeze conditions, this instrument provides rapid 0.5-second sampling to capture instantaneous fluctuations accurately.
Certified Quality and Safety Standards
Built for European professionals, the UNI-T UT363S meets rigorous safety requirements and is fully CE and UKCA certified. Its robust housing withstands 1-metre drops, providing long-term reliability in workshop and field applications. The unit offers an intuitive control layout, enabling fast selection among 5 wind speed units, temperature conversion, and real-time wind scale tracking.
Technical Specifications
| Wind Speed Measurement (m/s) | 0.4 ~ 30 m/s; ±(5% + 0.5 m/s) |
|---|---|
| Wind Speed Measurement (km/h) | 1.4 ~ 108 km/h; ±(5% + 1.5 km/h) |
| Wind Speed Measurement (ft/min) | 78 ~ 5905 ft/min; ±(5% + 100 ft/min) |
| Wind Speed Measurement (knots) | 0.7 ~ 58 knots; ±(5% + 1 knot) |
| Wind Speed Measurement (mph) | 0.8 ~ 67 mph; ±(5% + 1 mph) |
| Wind Speed Resolution | 0.01 (0~99), 0.1 (100~999), 1 (≥1000) |
| Temperature Range | -10 ~ 50°C (14 ~ 122°F); ±2.0°C (±4.0°F) |
| Temperature Resolution | 0.1°C / 0.2°F |
| Wind Scale Range | 0 ~ 12 (Accuracy: ±1) |
| Sampling Rate | 0.5 s (2 measurements/s) |
| Display Size | 35 x 32 mm with Backlight |
| Drop Test Rating | 1 metre |
| Operating Temperature | 0°C ~ 40°C |
| Power Supply | 3x 1.5V AAA / R03 Batteries |
| Dimensions & Net Weight | 120 x 53 x 43 mm; 365 g |
| Certifications | CE, UKCA |
Frequently Asked Questions
What are the benefits of a split-type anemometer?
A split-type anemometer features an external probe tethered to the display unit. This setup allows you to position the vane sensor directly inside diffusers, extract grills, or machinery while holding the readout comfortably in your hand at eye level.
Can the UT363S measure ambient air temperature simultaneously?
Yes, the sensor head incorporates a temperature sensor that monitors airflow temperature from -10°C to 50°C (14°F to 122°F) concurrently with wind velocity.
What is the Beaufort wind scale display on the device?
The meter automatically calculates and displays the current wind scale level from 0 to 12, offering immediate assessment of breeze and wind intensity alongside exact numerical measurements.
What accessories are included with the meter?
The package comes complete with the UT363S main unit, the external vane sensor head, 3x 1.5V AAA batteries, and an English user manual.
Does the device meet European regulatory standards?
Yes, the UNI-T UT363S is fully certified to CE and UKCA standards, ensuring full safety, electromagnetic compatibility, and reliability for commercial and industrial use across the EU.
| Product number: | 202741 |
|---|
| Flyer: | UT363S%20Datasheet.pdf?ts=1789593870 |
|---|---|
| Other documents: | UT363S%20User%20Manual%20English.pdf?ts=1789593883 |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.