| Product number: | 202714 |
|---|---|
| Manufacturer number: | UT372D |
| EAN | 6935750537213 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Main Product-Features
- 2-in-1 Measurement Principle: Combines non-contact (optical) and contact-based (mechanical) measurements in one device for maximum flexibility.
- Comprehensive Measurement Modes: Measures rotational speed (RPM), frequency (Hz), surface velocity (m/min, ft/min, in/min), and length (m, ft, in).
- High Precision: Offers an impressive accuracy of ±0.02% ±1 digit for reliable measurement results.
- Bluetooth Connectivity: Connect the device to the iENV app on your smartphone for data analysis and recording.
- Innovative Display: Large, rotatable LCD display with switchable backlight for the best readability from any angle.
- Data Storage & Statistics: Stores up to 10 readings and displays MAX/MIN/AVG/Last value.
- Robust & Safe: Successfully tested for a 1-meter drop and CE certified for safe use in Europe.
- Auto Power Off: Saves energy by automatically shutting down after about 15 minutes of inactivity.
Two Measurement Methods, Infinite Possibilities: The UT372D
The Flexible All-Rounder for Your Speed Analysis
Imagine you are facing a complex machine. Some parts are easily accessible, while others rotate behind a protective cover. With conventional measuring devices, you hit your limits here. Not so with the UNI-T UT372D. This 2-in-1 marvel of measurement technology gives you the freedom to choose the optimal method for every situation. Use the precise laser for a quick, non-contact measurement from a safe distance, or switch seamlessly to mechanical contact measurement for shafts and surfaces. This duality makes the UT372D an indispensable tool for maintenance staff, technicians, and engineers in the automotive industry, mechanical engineering, or when servicing ventilation systems.
Intelligent Features for the Modern Professional
The UT372D is more than just a measuring device – it's your smart partner. Thanks to the integrated Bluetooth interface, you can transfer your measurement data live to the iENV app. Analyze trends, create reports, and share results directly from the job site. The innovative, rotatable display ensures you always have a perfect view of the values, no matter how awkward the measurement spot is. Functions like data storage, and maximum, minimum, and average value display complete the package and simplify your daily work. Designed for professional use, the UT372D naturally complies with all relevant EU standards and is CE compliant, guaranteeing you safe and reliable operation.
| Specification | Range | Accuracy |
|---|---|---|
| Non-contact (optical) measurement | ||
| Rotational velocity (RPM) | 1 - 99,999 | ±0.02% ±1 digit |
| Frequency (Hz) | 1 - 1,666 | |
| Count (REV) | 1 - 99,999 | |
| Target distance | 50 - 500 mm | |
| Contact measurement | ||
| Rotational velocity (RPM) | 1 - 19,999 | ±0.02% ±1 digit |
| Frequency (Hz) | 1 - 333 | |
| Surface velocity | 0.1 - 1,999 m/min (0.1m wheel) / 0.15 - 1,524 m/min (6' wheel) | |
| Length | 0 - 99,999 (m/ft/in) | |
| General Characteristics | ||
| Battery type | 3x 1.5V AAA | |
| Dimensions | 176 x 63 x 38 mm | |
| Weight | Approx. 181g (without batteries) | |
| Certificates | CE, UKCA | |
Frequently Asked Questions (FAQ)
- What is included in the UT372D package?
- The package includes the UT372D device, a user manual, a quick start guide, safety instructions, various shaft contacts (cone/internal cone), contact wheels (6in/0.1m), a convenient cloth bag, and reflecting tape for optical measurement.
- Is the iENV app free?
- Yes, the corresponding iENV app for Android and iOS can be downloaded for free from the respective app stores.
- For which applications is the tachometer best suited?
- The UT372D is ideal for measurements on motors, fans, pumps, in the automotive industry, paper manufacturing, and general mechanical engineering.
| Product number: | 202714 |
|---|
| Flyer: | UT372D Datenblatt Data Sheet.pdf |
|---|---|
| Manual: | UT372D Anleitung Deutsch.pdf |
| Other documents: | UT372D User Manual (English).pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.