UNI-T UT622A Handheld LCR Meter with 0.1% Accuracy
| Quantity | Unit price |
|---|---|
| To 4 |
€175.00
|
| To 9 |
€166.25
|
| To 24 |
€157.50
|
| From 25 |
€149.00
|
Currently not available (delivery time on request)
| Product number: | 202613 |
|---|---|
| Manufacturer number: | UT622A |
| EAN | 6935750562215 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UT622A Handheld LCR Meter with 0.1% Accuracy"
Main Product Features
- Testing frequencies: 100 Hz, 120 Hz, 1 kHz, and 10 kHz
- Measurement accuracy up to 0.1% with 99,999 display counts
- Primary parameters: Inductance (L), Capacitance (C), Resistance (R), Impedance (Z)
- Secondary parameters: Dissipation Factor (D), Quality Factor (Q), Phase Angle (θ), ESR
- Selectable test signal levels: 0.1 Vrms, 0.3 Vrms, and 1.0 Vrms at 100 Ω output impedance
- 2.8-inch TFT LCD display (320 x 240) with 10 brightness levels
- Rechargeable 3.7 V 1800 mAh lithium-polymer battery providing up to 8 hours of runtime
- Tolerance sorting mode (1% to 20%) with visual LED indicator and audible alarm
Comprehensive Passive Component Testing
The UNI-T UT622A handheld LCR meter supports electronic design engineers, service workshops, and production testing facilities in evaluating passive components. Featuring automatic component identification, the instrument automatically selects appropriate series or parallel equivalent circuits. Primary values such as inductance, capacitance, resistance, and impedance are measured alongside secondary characteristics including dissipation factor, quality factor, phase angle, and ESR.
Inspection and Tolerance Comparison Features
For batch testing and incoming inspection, the instrument includes an integrated tolerance sorting mode adjustable from 1% to 20%. Green and red LEDs provide immediate pass/fail feedback alongside an optional audible alert. Statistical functions track minimum, maximum, and average readings, enabling operators to analyse component distributions efficiently during quality control workflows.
Signal Customisation and Lead Zeroing
Four test frequencies up to 10 kHz and three selectable voltage levels (0.1 Vrms, 0.3 Vrms, and 1.0 Vrms) allow adaptation to specific testing criteria. Parasitic influences from test leads can be eliminated using open- and short-circuit zero compensation. Components can be connected directly via front-panel 5-terminal insertion slots or through the 3-terminal banana jacks using the supplied test leads.
Power Management and Interface Connectivity
The integrated 3.7 V 1800 mAh lithium-polymer battery provides up to 8 hours of runtime, supported by a selectable automatic power-off feature after periods of inactivity. A fold-out stand allows convenient benchtop placement, while the 2.8-inch TFT colour display features ten brightness levels. The Mini-USB port facilitates data transfer to a PC and serves as the charging input.
| Model | UT622A |
| Test Frequencies | 100 Hz, 120 Hz, 1 kHz, 10 kHz |
| Test Signal Levels | 0.1 Vrms, 0.3 Vrms, 1 Vrms |
| Output Impedance | 100 Ω |
| Maximum Accuracy | 0.1% |
| Display Counts | 99,999 |
| Inductance (L) Range | 0.00 µH – 99.999 H |
| Capacitance (C) Range | 0.00 pF – 99.999 mF |
| Resistance/Impedance (R/Z) Range | 0.0000 Ω – 9.9999 MΩ |
| ESR Range | 0.0000 Ω – 999.99 Ω |
| Dissipation Factor (D) Range | 0.0000 – 9.9999 |
| Quality Factor (Q) Range | 0.0000 – 99999 |
| Phase Angle (θ) Range | -179.9° – 179.9° |
| Test Terminals | 3-terminal test jacks, 5-terminal test sockets |
| Measurement Speed | Fast (20/s), Medium (5/s), Slow (2/s) |
| Tolerance Range | 1% – 20% |
| Fuse Protection | 0.1 A / 250 V |
| Display | 2.8-inch TFT LCD (320 x 240) |
| Interface | Mini-USB |
| Battery | 3.7 V 1800 mAh Li-polymer |
| Battery Life | approx. 8 hours |
| Dimensions (W x H x D) | 93 mm x 192 mm x 44 mm |
| Weight | 420 g |
FAQ
Which test frequencies does the UT622A support?
The UT622A operates at 100 Hz, 120 Hz, 1 kHz, and 10 kHz.
Can the device perform open- and short-circuit zero compensation?
Yes, open and short clearing correction is integrated to remove parasitic effects from test leads.
How long is the battery operating time?
The built-in 1800 mAh lithium-polymer battery provides approximately 8 hours of continuous operation.
How are tolerance test results indicated?
Results are indicated by a visual LED alarm (green for pass, red for fail) as well as an audible beeper.
| Product number: | 202613 |
|---|
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280