Main Product-Features
- Large 4.3-Inch Display: Crystal-clear image reproduction with a resolution of 1280x720 pixels for detailed real-time analysis.
- Long and Flexible 5-Meter Probe: Effortlessly reach deep and winding areas. The flexible yet shape-retaining hose can be positioned precisely.
- Waterproof IP67 Camera: The 8mm camera probe is dust and waterproof, making it ideal for inspections in damp or dirty environments like drain pipes or engines.
- Bright LED Illumination: Eight adjustable LEDs on the camera head ensure perfect illumination even in complete darkness.
- Long Battery Life: The powerful 2000mAh lithium-ion battery allows for an uninterrupted working time of up to 6 hours.
- Comprehensive Image Functions: Benefit from image rotation, contrast adjustment, zoom functions, and color conversion directly on the device.
- Complete Accessory Package: The scope of delivery includes a hook, side mirror, magnet, and fixing buckles to expand your inspection capabilities.
- Robust and Ergonomic: The handheld unit is designed to be shock-resistant and non-slip, and it fits securely in your hand thanks to its ergonomic design.
Explore the Unseen with Precision and Clarity
Crystal-Clear Insights Where the Eye Can't Reach
Imagine you need to inspect the inside of an engine, locate a blockage in a drain pipe, or check the wiring in a wall without having to dismantle everything. The UNI-T UT665P-5m Industrial Borescope is your reliable eye for inaccessible areas. With its 5-meter long probe and high-resolution camera on the brilliant 4.3-inch display, no detail will escape you. The intuitive operation and robust design make it the perfect tool for craftsmen, car mechanics, plumbers, and ambitious DIY enthusiasts.
Safety and Reliability to EU Standards
With professional tools, safety comes first. Rely on a product that is not only powerful but also completely safe. The UT665P-5m is fully CE compliant and meets all strict EU standards for safety and quality. The replaceable hose with a sturdy aviation plug connection ensures a stable connection and durability in the tough daily work routine. Work with the confidence of using a tested and safe device.
Technical Data in Detail
| Feature | Specification |
|---|---|
| Model | UT665P-5m |
| Screen Size | 4.3 inches |
| Screen Resolution | 1280x720 pixels |
| Hose Length | 5 meters |
| Hose Material | Replaceable hardwire with aviation plug |
| Lens Diameter | 8 mm |
| Image Sensor | CMOS |
| Field of View (FOV) | 70° |
| Depth of Field (DOF) | 20 mm - 100 mm |
| Illumination | 8 LEDs, adjustable in 4 settings |
| Camera Pixels | 300,000 (300K) |
| IP Rating (Camera) | IP67 (dust and waterproof) |
| Battery | 3.7V / 2000mAh Lithium-Ion |
| Battery Life | approx. 6 hours |
| Working Temperature | 0°C to 45°C |
| Lens Temperature | 0°C to 80°C |
| Certifications | CE, RoHS |
Frequently Asked Questions (FAQ)
Is the camera truly waterproof?
Yes, the camera head with the lens is IP67 certified. This means it is completely dustproof and can be submerged in 1 meter of water for up to 30 minutes. The handheld unit itself is not waterproof.
How long does the battery last and how is it charged?
The battery has a capacity of 2000mAh and provides an operating time of about 6 hours. It is conveniently charged via the included Type-C cable.
What is included in the package?
In addition to the borescope handheld unit and the 5m probe, you will receive a Type-C charging cable, a gift box, a user manual, a blister tray, as well as the attachments: hook, side mirror, and magnet with three fixing buckles.
| Product number: | 202725 |
|---|
| Flyer: | UT665P User Manual English 2.pdf |
|---|---|
| Manual: | UT665P Anleitung Deutsch 2.pdf |
| Other documents: | UT665P Datenblatt Data Sheet 2.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.