| Product number: | 202719 |
|---|---|
| Manufacturer number: | UT665P |
| EAN | 6935750566510 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Main Product-Features
- Crystal Clear Image: Large 4.3-inch display with a resolution of 1280x720 pixels for clear and detailed insights.
- Compact & Robust Probe: The 8mm camera probe is IP67 dustproof and waterproof, reaching even the tightest spaces.
- Optimal Illumination: 8 adjustable LEDs at the camera tip ensure perfect visibility, even in complete darkness.
- Long Operational Readiness: The powerful 2000mAh lithium-ion battery allows for an operating time of up to 6 hours.
- Flexible Gooseneck: The 1-meter long, shapeable probe tube can be precisely bent into the desired position.
- Comprehensive Image Control: Functions like image rotation, zoom, contrast adjustment, and color inversion enable perfect analysis.
- Practical Accessories: The package includes a hook, side mirror, and a magnet attachment to retrieve objects or look around corners.
- Certified Safety: The device is CE and RoHS compliant, meeting all European safety standards.
See Where Others Are in the Dark
Precision for Demanding Inspections
Imagine you need to inspect a hard-to-reach cavity in an engine block, a clogged pipeline, or the wiring behind a wall. This is impossible with the naked eye. This is where the UNI-T UT665P Industrial Borescope comes in. It is your extended eye, delivering crystal-clear images from the most hidden corners. The 4.3-inch HD screen shows you every detail in brilliant quality, while the eight dimmable LEDs at the camera tip illuminate the darkest areas as if it were day. Thanks to the flexible yet sturdy 1-meter gooseneck, you can effortlessly navigate the camera through complex structures.
Robustness and Safety for Professional Daily Use
In the rough and tumble of daily work, reliability is key. The UT665P is built for it. The camera probe is IP67 certified, making it completely protected against dust and temporary immersion in water. Whether in oily engines or damp drainpipes – this endoscope holds up. A crucial factor for professional use is safety. You can rely on a product developed according to strict EU standards that meets CE conformity. This guarantees maximum operational safety and compliance with all relevant regulations. The ergonomic, non-slip handle also ensures secure handling, even under difficult conditions.
| Feature | Specification |
|---|---|
| Display Size | 4.3 inches |
| Display Resolution | 1280 x 720 pixels |
| Probe Diameter | 8 mm |
| Probe Length | 1 meter |
| Camera Protection | IP67 |
| Field of View (FOV) | 70° |
| Depth of Field (DOF) | 20 mm - 100 mm |
| Light Source | 8 adjustable LEDs (4 levels) |
| Battery | 3.7V / 2000mAh Li-Ion |
| Battery Life | approx. 6 hours |
| Operating Temperature | 0°C to 45°C |
| Lens Temperature | 0°C to 80°C |
| Certifications | CE, RoHS |
| Accessories | Hook, Side Mirror, Magnet, Type-C Cable, Fixing Buckles |
Frequently Asked Questions (FAQ)
- What applications is the UT665P suitable for?
- It is ideal for inspections in the automotive industry (engine, transmission), HVAC sector (air ducts), plumbing installations (pipes, drains), and construction (cavities, walls).
- Is the camera probe waterproof?
- Yes, the camera probe has an IP67 protection rating. It is dustproof and can be submerged in 1 meter of water for up to 30 minutes.
- How long does the battery last on a full charge?
- The 2000mAh battery provides an impressive operating time of up to 6 hours, depending on the set LED brightness.
- Can the brightness of the LEDs be adjusted?
- Yes, the brightness of the 8 LEDs can be adjusted in 4 levels directly on the device to optimally adapt the lighting to the environment.
| Product number: | 202719 |
|---|
| Flyer: | UT665P Datenblatt Data Sheet.pdf |
|---|---|
| Manual: | UT665P Anleitung Deutsch.pdf |
| Other documents: | UT665P User Manual English.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.