UNI-T UT665P Industrial Borescope with 4.3 Inch HD Display and IP67 Probe
€29.40
Currently not available (delivery time on request)
| Product number: | 202719 |
|---|---|
| Manufacturer number: | UT665P |
| EAN | 6935750566510 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UT665P Industrial Borescope with 4.3 Inch HD Display and IP67 Probe"
Main Product Features
- Color Display: 4.3-inch HD screen with 1280x720 pixel resolution and 178° viewing angle
- Camera Probe: 8 mm diameter CMOS sensor with 300K pixels and IP67 water and dust protection
- Illumination: 8 integrated LEDs at the camera tip with 4-level brightness adjustment
- Probe Length: 1-meter semi-rigid formable tube with detachable aviation plug connector
- Optical Focus: Depth of field from 20 mm to 100 mm with a 70° field of view (FOV)
- Image Control: On-screen image rotation, zoom-in and zoom-out, contrast adjustment, and color inversion
- Power Supply: Integrated 3.7 V / 2000 mAh rechargeable Li-ion battery for up to 6 hours of operation
- Charging Port: Type-C direct charging input (5 V / 1 A)
Industrial Visual Inspection for Diagnostics and Maintenance
The UNI-T UT665P industrial borescope is engineered for non-destructive visual checks in confined spatial environments. Automotive technicians use the instrument to inspect engine cylinders, valves, and gearboxes without extensive disassembly. In building maintenance, plumbing, and HVAC systems, it assists in assessing ventilation ducts, drainage pipes, and structural voids inside drywall or flooring installations.
Optical Performance and Real-Time Image Adjustments
Equipped with an 8 mm CMOS sensor offering 300,000 pixels, the probe delivers detailed live visuals directly to the 4.3-inch HD screen (1280 x 720 pixels) with a 178° viewing angle. The camera provides a 70° field of view and maintains optical focus within a depth of field between 20 mm and 100 mm. For dark environments, 8 probe-mounted LEDs offer four brightness settings to prevent glare on reflective metal or wet surfaces. Diagnostic functions include image flipping, digital magnification, contrast tuning, color inversion, and a dedicated black-and-white mode.
Semi-Rigid Probe Construction and Protection
The 1-meter formable tube retains its bend during routing through complex conduit bends and narrow pipelines. It attaches securely to the main handheld unit via a threaded aviation-style connector, ensuring simple probe replacement when required. Rated to IP67, the camera head is protected against dust ingress and temporary submersion in water, while the lens can withstand operational temperatures between 0 °C and 80 °C.
Rechargeable Power and Retrieval Accessories
A built-in 3.7 V / 2000 mAh lithium-ion battery provides up to 6 hours of continuous field operation, reloaded via a standardized Type-C interface at 5 V / 1 A. The system package includes the UT665P handheld unit, the 1 m probe, a charging cable, and essential head attachments: a 90° side-view mirror for inspecting pipe walls, along with a magnet and hook to retrieve dropped mechanical components from deep cavities.
| Display Size | 4.3 inches TFT LCD |
| Display Resolution | 1280 x 720 pixels |
| Viewing Angle | 178° |
| Camera Sensor | CMOS, 300K pixels |
| Probe Diameter | 8 mm |
| Probe Length | 1 m (semi-rigid hardwire) |
| Probe Protection Rating | IP67 |
| Field of View (FOV) | 70° |
| Depth of Field (DOF) | 20 mm to 100 mm |
| Camera Illumination | 8 LEDs, 4 adjustable brightness levels |
| Battery Type | 3.7 V / 2000 mAh Li-ion rechargeable |
| Battery Operating Time | Approx. 6 hours |
| Charging Interface | Type-C (5 V / 1 A) |
| Operating Temperature | 0 °C to 45 °C |
| Operating Humidity | <90% RH (non-condensing) |
| Lens Working Temperature | 0 °C to 80 °C |
| Handheld Unit Dimensions | 256 x 120 x 50 mm |
| Weight (Handheld Unit) | Approx. 270 g (excluding hose) |
FAQ
What does the IP67 rating cover?
The IP67 protection rating applies to the 8 mm camera probe and lens, protecting it against dust ingress and temporary immersion in water.
Can the probe tube be detached or replaced?
Yes, the probe tube connects to the main handheld unit via a threaded aviation plug and can be detached or exchanged.
What is the focal range of the camera?
The camera features a fixed-focus depth of field ranging from 20 mm to 100 mm from the lens tip.
How is the UT665P charged?
The integrated 2000 mAh lithium-ion battery charges via the included Type-C cable using a standard 5 V / 1 A power source.
What accessories are included for retrieving items?
The unit includes a hook, a magnet, and a side-view mirror that attach directly to the camera head using the provided fixing buckles.
| Product number: | 202719 |
|---|
| Flyer: | UT665P Datenblatt Data Sheet.pdf |
|---|---|
| Manual: | UT665P Anleitung Deutsch.pdf |
| Other documents: | UT665P User Manual English.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.