Main Product-Features
- Large 4.3-inch IPS Display: Crystal-clear real-time images and videos with a resolution of 1280x720 pixels for detailed analysis.
- 5-Meter Long Rigid Cable: Effortlessly reach deep and hard-to-access areas in engines, pipes, or walls.
- Compact 8mm Camera Head: The slim camera fits through the narrowest openings and delivers sharp images thanks to its CMOS sensor.
- IP67-Rated Camera: The camera probe is completely dustproof and waterproof, making it ideal for inspections in damp or wet environments.
- Powerful LED Illumination: Eight adjustable LEDs ensure perfect lighting even in complete darkness.
- Long Battery Life: The integrated 2000mAh lithium-ion battery allows for an operating time of up to 5 hours for extended use.
- Intuitive Image Control: Features such as image rotation, zoom, black-and-white view, and color conversion directly on the device.
- Comprehensive Accessories: Includes a hook, side mirror, magnet, and fixing clips to retrieve objects or change the viewing angle.
Precision in Unreachable Depths: The UNI-T UT667-5m
For Professionals Who Make No Compromises
Imagine having to find a fault deep inside a complex machine, engine, or a laid pipe. In the past, this often meant time-consuming and costly disassembly. With the UNI-T UT667-5m Industrial Endoscope, this effort is a thing of the past. This state-of-the-art inspection tool is your eye in areas that would otherwise remain hidden. The 5-meter long, shapeable cable can be precisely guided through winding channels, while you see every detail in sharp focus on the brilliant 4.3-inch IPS display. Whether it's hairline cracks in the cylinder head, blockages in drainpipes, or faulty wiring in walls – the UT667-5m provides you with the visual information you need to make a quick and informed decision.
Safety and Reliability for Every Inspection
In professional work environments, safety is paramount. Rely on a tool that is not only powerful but also completely safe. The UT667-5m is, of course, CE certified and meets all strict EU standards for operational safety and quality. Its robust construction, IP67-protected camera, and reliable battery make it the perfect partner for daily use in workshops, industry, and trade. Save time, reduce costs, and increase the efficiency of your inspections with this indispensable diagnostic tool.
| Feature | Specification |
|---|---|
| Model | UT667-5m |
| Screen Size | 4.3 inch IPS LCD |
| Screen Resolution | 1280 x 720 pixels |
| Probe Length | 5 meters |
| Probe Material | Replaceable hardwire with aviation plug |
| Camera Diameter | 8 mm |
| Camera IP Rating | IP67 |
| Image Sensor | CMOS |
| Pixels | 300K |
| Field of View (FOV) | 70° |
| Depth of Field (DOF) | 20 mm - 100 mm |
| Illumination | 8 LEDs, 4-setting adjustable |
| Battery | 3.7V / 2000mAh Lithium-ion |
| Battery Life | Approx. 5 hours |
| Working Temperature | 0°C to 45°C |
| Certifications | CE, RoHS |
| Functions | Image rotation, zoom, black-white mode, color conversion |
| Accessories Included | Hook, side mirror, magnet, 3x fixed buckles, Type-C charging cable, user manual |
Frequently Asked Questions (FAQ)
Is the probe cable of the UT667-5m replaceable?
Yes, the cable is connected to the handheld unit via a sturdy aviation plug and can be replaced if necessary. Other lengths (1m, 10m) are also available.
Can I use the camera to inspect underwater?
Absolutely. The camera probe is IP67 certified, which means it is dustproof and can withstand temporary immersion in water. However, the handheld unit itself is not waterproof.
How is the device charged and how long does it take?
The endoscope is charged via the included Type-C USB cable. The charging time depends on the power adapter used, but it usually takes a few hours for a full charge.
| Product number: | 202726 |
|---|
| Flyer: | UT667 Datenblatt Data Sheet 2.pdf |
|---|---|
| Manual: | UT667 User Manual English 2.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.