Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi120B Thermal Imaging Camera 120 x 90 IR Resolution

Product information "UNI-T UTi120B Thermal Imaging Camera 120 x 90 IR Resolution"

Main Product Features

  • Crisp 120 x 90 pixel infrared resolution for fast, reliable diagnostic imaging
  • Wide temperature measurement span suitable for diverse inspection environments
  • Vibrant colour display with multiple selectable thermal palettes
  • Auto hot and cold spot tracking for effortless fault identification
  • Rugged, ergonomic handheld housing engineered for daily on-site work
  • Rechargeable battery providing continuous mobile runtime
  • On-board storage and easy data transfer for comprehensive reporting

Professional Diagnostics Made Accessible

Thermal anomalies are often invisible to the naked eye until costly downtime or severe damage occurs. The UNI-T UTi120B bridges the gap between basic infrared thermometers and complex high-end thermography gear, delivering genuine diagnostic confidence in a compact, intuitive handheld format. Equipped with a reliable 120 x 90 infrared sensor, this thermal imaging camera lets technicians, engineers, and facility managers immediately detect abnormal heat patterns across machinery, distribution boards, and building envelopes.

Uncover Electrical and Mechanical Vulnerabilities

Whether tracking down overloaded circuit breakers, loose terminal connections, unbalanced three-phase loads, or failing motor bearings, the UTi120B streamlines troubleshooting. Instead of manually inspecting points with a spot pyrometer, the unit visualises the entire scene instantly. Dynamic on-screen markers immediately highlight the hottest and coldest spots within your frame, allowing you to pinpoint potential failure points long before components overheat or fail catastrophically.

Optimise HVAC Performance and Building Efficiency

Energy loss, defective underfloor heating loops, thermal bridging, and missing insulation are quickly exposed with the UTi120B. Heating and ventilation technicians can trace pipe runs behind surfaces, check radiator heat distribution, and identify leaking ductwork in seconds. Building evaluators benefit from high-contrast thermal views that substantiate efficiency audits with clear, undeniable visual evidence.

Streamlined Workflow and Intuitive Operation

Designed with practicality in mind, the camera powers on quickly and presents critical thermal data without steep learning curves. Multiple colour palettes allow users to tailor the visual output to specific diagnostic contexts—such as using Ironbow for electrical panels or Rainbow for architectural inspections. Captured thermal files can be transferred directly to a computer, ensuring documentation and customer reporting are straightforward, fast, and professional.

Technical Specifications

ModelUNI-T UTi120B
IR Resolution120 x 90 pixels
DisplayTFT LCD colour screen
PalettesMultiple selectable colour palettes
TrackingAutomatic hot and cold spot detection
StorageRemovable micro SD / internal storage support
Power SupplyRechargeable Lithium-ion battery
InterfaceUSB Type-C connectivity

Frequently Asked Questions

What are the primary differences between this camera and an infrared thermometer?

A standard infrared thermometer measures only a single averaged surface point. The UTi120B provides an entire visual thermal map with over ten thousand individual measurement points, revealing thermal distributions, gradients, and subtle heat signatures across an entire component or area at once.

Can the UTi120B locate underfloor heating pipes and water leaks?

Yes. By displaying surface temperature variations, the camera clearly outlines the paths of active warm water pipes and reveals localized cool spots where hidden moisture or structural dampness may be accumulating.

How are thermal images saved and transferred for reporting?

Images captured with the trigger are stored directly to memory. You can transfer saved files to a PC using the supplied USB connection to generate comprehensive customer reports and repair logs.

Is this camera suitable for outdoor building inspections?

Yes, provided there is a measurable temperature differential between the inside and outside of the building. The camera performs effectively for detecting missing insulation, cold drafts, and structural thermal bridges.

Technical data
Product number: 202593
Alarm: ✓
Auto tracking for Lo/Hi temperature: ✓
Communication Interface: USB Type-C
Digital Camera: 648 x 488 pixels
Emissivity: Adjustable (0.01-1)
Field Of View: 51°x38°
Focus: Focus free
Framerate: 25Hz
Image Model: Thermal, visible, blending
IR Resolution: 120x90 pixels
LED: ✓
Palettes: 7
PC Software: Analysis, Real-time display
Protection: IP65/2m
ROI: ✓
Weight: 0.91kg
Size: 236mm x 75.5mm x 86mm
Size: 236mm x 75.5mm x 86mm
Weight: 0.91kg

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.