Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi120M Smartphone Thermal Camera 120x90 USB-C

Product information "UNI-T UTi120M Smartphone Thermal Camera 120x90 USB-C"

Main Product Features

  • IR Resolution: 120×90 pixels for clear thermal diagnostics
  • Wide Temperature Measurement Range: -20°C to 400°C
  • High Thermal Sensitivity: NETD ≤60mK @25°C detects minor temperature shifts
  • Plug-and-Play USB Type-C interface for direct smartphone connectivity (Android Smartphones)
  • Versatile Image Modes: Thermal, Fusion, and Picture-in-Picture (PIP)
  • Smooth Real-Time Imaging: Up to 25Hz frame rate with focus-free operation
  • 7 Dynamic Colour Palettes: White hot, Lava, Ironbow, Black hot, Red hot, Rainbow, and Rainbow HC
  • Comprehensive On-Screen Analysis: 6 Points, 6 Lines, 6 Rectangles, and 6 Circles
  • Automatic High and Low Temperature Alarms
  • Compact, lightweight construction (25g) with certified 2m drop resistance

Transform Your Smartphone into a Professional Thermal Imager

The UNI-T UTi120M turns your USB Type-C smartphone into an advanced thermal imaging tool. Engineered for technicians, maintenance personnel, electrical contractors, and DIY enthusiasts, this pocket-sized device eliminates bulky inspection equipment without compromising diagnostic accuracy. With a sensor resolution of 120×90 pixels and a wide field of view (50°×38°), it captures clear thermal pictures and dynamic videos directly on your mobile device screen.

Precise Thermal Detection and Advanced Analysis

Covering an expansive temperature range from -20°C to 400°C with an accuracy of ±2°C or ±2%, the UTi120M identifies critical heat signatures instantly. An exceptional thermal sensitivity of ≤60mK ensures that subtle temperature differentials are visible, allowing you to catch emerging issues before costly failures occur. The dedicated mobile application delivers comprehensive real-time screen analysis, supporting simultaneously up to 6 custom measurement points, 6 lines, 6 rectangles, and 6 circles. Visual high- and low-temperature alarms provide instant alerts when preconfigured thresholds are exceeded.

Versatile Display Modes and Comprehensive Reporting

Adapt to diverse inspection environments by selecting between Thermal, Fusion, and Picture-in-Picture (PIP) modes. Seven distinct colour palettes—White hot, Lava, Ironbow, Black hot, Red hot, Rainbow, and Rainbow HC—let you optimise contrast for electrical panels, HVAC pipes, or insulation checks. Capture high-resolution JPEG images or MP4 videos on the fly, and compile professional PDF inspection reports directly within the app for swift sharing with clients or team members.

Rugged, Lightweight, and Field-Ready

Weighing only 25g and measuring 53mm×18.2mm×18.5mm, the UTi120M fits comfortably in your pocket or tool belt. Despite its miniature format, it features a robust build that withstands drops of up to 2 metres, ensuring reliable performance in demanding field environments from construction sites to industrial control cabinets.

Typical Applications

  • Electrical Maintenance: Detect overloaded breakers, loose terminal connections, and imbalanced loads in distribution boards.
  • HVAC & Plumbing: Locate underfloor heating blockages, inspect ductwork for leaks, and verify air conditioning efficiency.
  • Electronics & PCBA Inspection: Quickly identify overheating surface-mount components, short circuits, and power supply flaws.
  • Building Diagnostics: Uncover missing insulation, thermal bridges, and moisture accumulation around doors and windows.
ParameterSpecification
IR Resolution120×90 pixels
Field of View (FOV)50° × 38°
Thermal Sensitivity (NETD)≤60mK @25°C
Spatial Resolution (IFOV)7.3mrad
Frame Rate≤25Hz
FocusFocus free
Lens Focal Length2.28mm
Temperature Range-20°C to 400°C
Measurement Accuracy±2°C or ±2% (whichever is greater)
Emissivity0.1 to 1.00 adjustable (default 0.95)
Image ModesThermal, Fusion, PIP
Colour PalettesWhite hot, Lava, Ironbow, Black hot, Red hot, Rainbow, Rainbow HC
On-Screen Analyzer6 Points, 6 Lines, 6 Rectangles, 6 Circles
AlarmsAutomatic high and low temperature alert
Media FormatPhoto: JPEG; Video: MP4
InterfaceUSB Type-C
Drop Resistance2 metres
Product Dimensions53mm × 18.2mm × 18.5mm
Net Weight25g

Frequently Asked Questions

What devices are compatible with the UTi120M?

The UTi120M is compatible with smartphones featuring a USB Type-C port and running the dedicated companion thermal analysis app.

Does the camera require manual focusing?

No, the UTi120M features a focus-free design with a 2.28mm focal length, delivering sharp thermal images across standard inspection distances automatically.

Can I export and share thermal inspection reports?

Yes, the software application allows you to capture JPEG photos and MP4 videos, as well as generate comprehensive PDF inspection reports that can be shared immediately via email or messaging apps.

Does the UTi120M require an internal battery?

No, the camera is powered directly through your smartphone USB Type-C connection, meaning you never need to charge a separate camera battery before conducting an inspection.

What is included in the package?

The package contains the UNI-T UTi120M thermal camera, an English user manual, and a documents download operation guide card.

Technical data
Product number: 202641

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.