Main Product Features

  • Infrared resolution: 120 × 90 pixels for clear thermal diagnostics
  • Wide temperature measurement range from -20°C up to 400°C
  • Thermal sensitivity (NETD) of ≤60mK to detect subtle temperature variations
  • Compact, pocket-sized housing weighing only 125 g
  • Clear 2.4-inch TFT LCD with 320 × 240 resolution
  • Focus-free system with a wide 50° × 38° field of view
  • Automatic high and low temperature tracking with icon-based alert
  • Three selectable colour palettes: Ironbow, Grey, and Rainbow
  • Robust design offering 1 m drop resistance
  • Integrated 3.7V 1350mAh Li-ion battery providing ≥3.5 hours of continuous operation
  • Supports PC software analysis and storage via Micro SD cards up to 32 GB

Pocket-Sized Thermal Inspection for Fast Troubleshooting

The UNI-T UTi120P is an ultra-compact, lightweight thermal camera engineered for technicians, facility managers, and electricians who require swift, non-destructive diagnostic capabilities in a go-anywhere format. Weighing a mere 125 grams and measuring just 76 mm across, this thermal imager slips effortlessly into any shirt pocket or tool pouch, ensuring high-grade thermographic analysis is always within arm's reach.

Reliable Infrared Precision and Performance

At the core of the UTi120P is an uncooled thermal sensor delivering an IR resolution of 120 × 90 pixels coupled with an NETD of ≤60mK. With an expansive measurement window from -20°C to 400°C and an accuracy of ±2°C or ±2%, this pocket instrument enables quick identification of overheating components, insulation voids, and thermal bridges. The focus-free optics and generous 50° × 38° field of view let you scan entire electrical panels or mechanical assemblies instantly without the need for manual focusing.

Smart Temperature Tracking and Clear Visualization

To expedite routine maintenance, the UTi120P features auto-tracking for peak hot and cold spots. The built-in icon-based alarm instantly warns operators when critical thresholds are exceeded, eliminating guesswork during urgent inspections. Thermal data is rendered smoothly at frame rates up to 25 Hz on the bright 2.4-inch display, with three adaptable colour palettes (Ironbow, Grey, Rainbow) tailored to diverse application environments.

Effortless Analysis and Everyday Durability

Images and videos are saved directly in standard BMP format on an optional Micro SD card (up to 32 GB), making documentation straightforward. By linking the device to dedicated PC analysis software via Micro USB, professionals can evaluate thermal maps, generate comprehensive reports, and share findings with clients. Engineered to survive harsh jobsite demands, the rugged casing withstands accidental drops from heights of up to 1 metre.

Versatile Applications Across Industries

Whether tracing underfloor heating leaks, pinpointing overloaded circuit breakers, surveying automotive engine bays, or checking printed circuit boards (PCBs) for thermal anomalies, the UTi120P delivers actionable thermal intelligence on demand. Its battery runtime of over 3.5 hours ensures uninterrupted uptime across full shifts.

Technical Specifications

ModelUNI-T UTi120P
IR Resolution120 × 90 pixels
Thermal Sensitivity (NETD)≤60mK
Spatial Resolution (IFOV)7.3 mrad
Temperature Measurement Range-20°C to 400°C
Measurement Accuracy±2°C or ±2% (whichever is greater)
Field of View (FOV)50° × 38°
FocusFocus free
Frame Rate≤25 Hz
Display2.4" TFT LCD (320 × 240)
EmissivityAdjustable 0.01 to 1.00 (0.95 default)
Colour PalettesIronbow, Grey, Rainbow
Image ModesThermal
AlarmsHigh/Low temperature icon alert
PC Software AnalysisSupported
Storage MediaMicro SD card (up to 32 GB)
File Storage FormatBMP (Image and Video)
InterfaceMicro USB
BatteryFixed Li-ion (3.7V, 1350mAh)
Battery Runtime≥3.5 hours
Drop Test Resistance1 m
Dimensions76 mm × 76 mm × 24 mm
Net Weight125 g

Frequently Asked Questions

What file format does the UTi120P use for saved images?

The camera stores thermal images and video files directly in BMP format, allowing convenient viewing on any computer or operating system.

Can the UTi120P be used for detailed reporting?

Yes, the device supports PC analysis software. Simply connect the camera via Micro USB to inspect captured thermal files, evaluate temperature values, and generate professional inspection reports.

Does the camera require manual focusing?

No, the UTi120P is completely focus free. This enables immediate point-and-shoot operation without needing to adjust the lens manually.

How long does the built-in rechargeable battery last?

The integrated 3.7V 1350mAh lithium-ion battery provides a continuous operational runtime of at least 3.5 hours on a full charge.

How robust is the UTi120P for jobsite use?

The UTi120P features a sturdy, pocket-sized construction designed to withstand impact and accidental drops from up to 1 metre.

Technical data
Product number: 202746

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.