Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi260B Robust Thermal Imaging Camera 256x192 IP65

Product information "UNI-T UTi260B Robust Thermal Imaging Camera 256x192 IP65"

Main Product Features

  • Crisp thermal imaging with 256 x 192 pixel infrared resolution
  • Extensive temperature measurement span from -20°C up to 550°C
  • Heavy-duty housing with IP65 water and dust resistance plus 2-metre drop proofing
  • Clear 2.8-inch LCD display for real-time diagnostics
  • Dual camera setup featuring thermal, visible light, blending, and picture-in-picture modes
  • Replaceable Li-ion rechargeable battery for extended on-site inspections
  • Fast 25 Hz frame rate for fluid, real-time thermal analysis
  • MicroSD card storage for seamless image archiving and reporting

Professional Diagnostics Made Tough and Precise

The UNI-T UTi260B thermal imaging camera is an indispensable tool designed for demanding field conditions, industrial maintenance, and facility diagnostics. Combining sharp 256 x 192 infrared sensor resolution with a ruggedised enclosure, this handheld thermal imager allows technicians, electricians, and engineers to detect thermal anomalies, identify insulation gaps, and inspect electrical panels with high precision and speed.

Built for Harsh Everyday Environments

Whether working in dusty manufacturing plants, damp utility tunnels, or outdoor job sites, the UTi260B stands up to the challenge. Boasting an IP65 rating, it resists ingress from water jets and dust, while the rubberised exterior absorbs shocks from accidental drops up to 2 metres. It is engineered from the ground up to endure real-world trade use without compromising delicate sensor performance.

Wide Temperature Range for Versatile Applications

With an expansive operating range covering -20°C up to 550°C, the instrument seamlessly adapts to diverse industries. From sub-zero refrigeration diagnostics and heat exchanger verification to high-temperature mechanical bearing checks, smelting equipment, and heavy industrial plant machinery, the camera delivers dependable thermal readouts across every critical point.

Intuitive Image Blending and Analysis

Finding the exact source of a problem is effortless thanks to versatile display modes. The integrated visible-light camera works in tandem with the thermal detector, enabling side-by-side comparison, picture-in-picture visualization, and multi-spectral blending. Highlight hot and cold spots instantly with customizable colour palettes, and store diagnostic captures directly to the memory card for reporting and client presentations.

Technical Specifications

ParameterSpecification
IR Sensor Resolution256 x 192 pixels
Temperature Measurement Range-20°C to 550°C
Display2.8-inch TFT LCD
Refresh Rate25 Hz
Ingress Protection RatingIP65
Drop ResistanceUp to 2 metres
Image ModesThermal, Visual, Blending, Picture-in-Picture
Data StorageMicroSD Card
Power SourceRechargeable Lithium-Ion Battery
ConnectivityUSB Type-C

Frequently Asked Questions

What type of environments is the IP65 rating suitable for?

An IP65 rating ensures that the unit is fully dust-tight and protected against low-pressure water jets from any angle, making it ideal for wet, dusty, and demanding industrial job sites.

Can I combine visual photos with thermal heat maps?

Yes, the camera incorporates dual lenses to provide image blending, visual reference photos, picture-in-picture views, and pure thermal views to help pinpoint faults rapidly.

Does the camera identify hot and cold spots automatically?

The unit features real-time dynamic tracking that automatically places markers on the hottest and coldest points visible within the frame.

How are thermal photos transferred to a computer?

Files saved on the included MicroSD card can be transferred directly via a card reader or by connecting the device via the included USB Type-C cable.

Is the device suitable for HVAC and electrical inspections?

Yes, with its high resolution and broad temperature capability, it is widely utilized for checking fuse boxes, underfloor heating, HVAC ducting, and motor heat build-up.

Technical data
Product number: 202704

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.