Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi32 Compact Thermal Imaging Camera -20°C to 1000°C

Product information "UNI-T UTi32 Compact Thermal Imaging Camera -20°C to 1000°C"

Main Product Features

  • Extensive measurement range from -20°C up to 1000°C for high-heat environments
  • Compact and lightweight design for effortless one-handed everyday operation
  • 32x32 pixel infrared resolution tailored for fast spot checks and surface diagnostics
  • Clear digital display providing immediate hot-and-cold point tracking
  • Rechargeable battery configuration offering reliable operation in the field
  • Adjustable emissivity settings to ensure accurate measurements across varied surfaces

Advanced High-Temperature Diagnostics in Your Pocket

The UNI-T UTi32 compact thermal imaging camera bridges the gap between traditional spot infrared thermometers and complex thermal imagers. Engineered specifically for technicians, maintenance engineers, and electricians, this pocket-sized powerhouse enables instant visual confirmation of thermal anomalies across an impressive temperature window from -20°C right up to 1000°C. Instead of guessing where heat loss, friction, or electrical overload occurs, the UTi32 gives you quick visual context, allowing you to identify critical issues before they lead to expensive downtime or equipment failure.

Engineered for Challenging Industrial Environments

Whether you are inspecting industrial furnaces, metal smelting operations, automotive exhaust systems, or high-voltage distribution boards, standard thermal imagers often hit their limits well below 500°C. The UTi32 is built to thrive where extreme heat is part of the daily workflow. Its ruggedized, palm-sized enclosure fits neatly into any toolbox or work vest pocket, ensuring you always have high-temperature diagnostics within arm's reach.

Streamlined Workflow and Intuitive Operation

Speed is essential during routine maintenance rounds. With intuitive controls and rapid boot-up times, the UTi32 lets you capture temperature gradients without navigating complicated multi-tier menus. On-screen indicators pinpoint dynamic high and low temperature points automatically, drastically cutting down inspection times during motor diagnostics, bearing assessments, and refractory insulation reviews.

Typical Applications

  • Electrical Maintenance: Detect overloaded breakers, loose busbar connections, and unbalanced loads quickly.
  • Automotive & Motorsport: Inspect brake disc heat dissipation, catalytic converters, and engine manifolds under load.
  • Manufacturing & Metalworking: Monitor induction heating, casting processes, and heat-treatment kilns.
  • Facility Management & HVAC: Locate steam trap failures, pipe blockages, and heating line distribution problems.

Technical Specifications

ParameterSpecification
ModelUNI-T UTi32
Thermal Resolution32 x 32 pixels
Temperature Measurement Range-20°C to 1000°C
Form FactorCompact pocket-sized handheld
Temperature TrackingAuto hot & cold spot detection
EmissivityAdjustable (surface-dependent)
Power SourceIntegrated rechargeable battery
Display TypeIntegrated colour LCD screen

Frequently Asked Questions

What makes the UTi32 suitable for high-temperature measurements?

The UTi32 features an optical sensor calibrated to read temperatures up to 1000°C, making it significantly more versatile than typical building diagnostics cameras that cap out around 150°C to 400°C.

Can I adjust the emissivity on the UTi32?

Yes, adjustable emissivity allows you to fine-tune the device according to the material you are inspecting, such as polished metals, painted surfaces, or refractory brickwork, ensuring maximum measurement consistency.

How does a 32x32 thermal camera compare to an infrared spot thermometer?

While an infrared spot thermometer gives you an averaged temperature of a single circle, the 32x32 array displays 1,024 individual temperature points simultaneously as a thermal image, allowing you to instantly see thermal distribution and find hotspots you might otherwise miss.

Is this camera suitable for everyday electrical inspections?

Absolutely. It is an ideal tool for rapid troubleshooting in fuse boxes, switchboards, and distribution panels to detect loose terminals and overloaded circuits before performing deeper analysis.

Technical data
Product number: 202702

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.