Main Product Features

  • Native IR resolution of 120 × 90 pixels enhanced to 240 × 180 pixels via Super Resolution technology
  • Wide temperature measurement range from -20 °C to 550 °C with ±2 °C or ±2% accuracy
  • Long-lasting 2600 mAh Li-ion battery providing an exceptional operating time of ≥13 hours
  • Rugged construction featuring IP54 ingress protection and certified 2 m drop resistance
  • Comprehensive HI/LO temperature tracking with triple alarms: LCD animation, LED flashlight, and audible buzzer
  • Focus-free optical system with a 50° × 38° field of view and smooth ≤25 Hz frame rate
  • Integrated LED work light and precision laser pointer for reliable target identification
  • Radiometric JPEG image capture supported by dedicated PC analysis software via USB-C

Enhanced Diagnostic Precision for Daily Maintenance

The UNI-T UTi712S+ represents a powerful leap forward in handheld thermography, combining accessible operation with advanced imaging technology. Engineered specifically for technicians, facility managers, and electrical engineers, this thermal imager reveals hidden thermal anomalies before they evolve into costly equipment failures. With its integrated Super Resolution capability, the camera quadruples native sensor data, elevating the standard 120 × 90 IR resolution to crisp 240 × 180 detail. This provides clearer edge definition and enhanced thermal contrast on its vibrant 2.4-inch TFT display, making subtle temperature differentials immediately evident.

Versatile Applications in HVAC, Electrical, and Mechanical Inspection

Designed to tackle a wide spectrum of industrial and domestic challenges, the UTi712S+ excels in detecting thermal bridges, insulation defects, and ductwork leakages across building HVAC systems. In electrical environments, technicians can quickly isolate overloaded breakers, loose terminations, and unbalanced phase loads from a safe distance, aided by the wide -20 °C to 550 °C temperature range. Mechanical maintenance crews benefit from non-contact friction analysis on bearings, motors, and pump housings, preventing catastrophic breakdown. Automotive specialists also rely on the camera for pinpointing misfiring cylinders, restricted cooling passages, and uneven brake rotor wear.

Built for Tough Environments and Continuous Workflow

Jobsite conditions demand equipment that can withstand rough handling. The UTi712S+ features a rugged housing engineered to resist impacts from up to 2 metres and is sealed against dust and splashing water to IP54 standards. Despite its robust nature, the device weighs only 313 grams and provides an ergonomic grip designed for all-day one-handed operation via a clear, 4-button interface. With an impressive battery autonomy of at least 13 hours on a single charge, professionals can conduct full-day field audits without worrying about recharging intervals.

Comprehensive Reporting and Palette Flexibility

Effective thermal diagnostics require precise documentation and tailored visualisation. The UTi712S+ offers six selectable colour palettes—White Hot, Black Hot, Ironbow, Lava, Rainbow, and Rainbow HC—allowing users to adapt the display to various material emissivities and lighting conditions. With capacity for approximately 2,300 radiometric JPEG files, each captured image stores temperature metadata at every pixel point. Connecting the unit to a computer through the modern USB Type-C interface enables in-depth thermal analysis, temperature compensation adjustments, and professional reporting through the companion PC software.

Technical Specifications

Display2.4-inch TFT LCD (320 × 240 pixels)
Native IR Resolution120 × 90 pixels
Super Resolution240 × 180 pixels
Thermal Sensitivity (NETD)≤60 mK
Pixel Pitch17 µm
Frame Rate≤25 Hz
Field of View (FOV)50° (H) × 38° (V)
FocusFocus Free
Temperature Measurement Range-20 °C to 550 °C
Measurement Accuracy±2 °C or ±2% (whichever is greater)
Colour PalettesWhite Hot, Black Hot, Ironbow, Lava, Rainbow, Rainbow HC
Image ModeThermal
Temperature CompensationSupported
AlarmsHI/LO tracking with LCD animation, LED flashlight, buzzer
Integrated ToolsLaser pointer, LED work light
Battery Type & Runtime2600 mAh Li-ion battery, ≥13 hours
Interface & StorageUSB Type-C; approx. 2,300 radiometric JPEG photos
Drop Test & Protection2 m drop proof; IP54
Dimensions & Weight197 mm × 72 mm × 60 mm; 313 g
Supported LanguagesEN, FR, DE, ES, IT, SV, PL, CS

Frequently Asked Questions

What does the Super Resolution feature achieve?

Super Resolution is an integrated algorithm that enhances the native 120 × 90 thermal detector output to 240 × 180 pixels. This produces a sharper, more detailed thermal image, making it easier to identify fine thermal variations and component edges.

How does the camera warn users of critical temperatures?

The UTi712S+ incorporates an active HI/LO temperature tracking system. When user-defined limits are exceeded, the camera alerts you through visual on-screen LCD animations, an integrated flashing LED light, and an audible buzzer.

Can I analyse captured images on a PC?

Yes. The camera saves images in radiometric JPEG format, retaining temperature information for every pixel. By connecting the device via USB Type-C, you can evaluate thermal values and prepare comprehensive inspection reports using the dedicated PC analysis software.

Is focusing required before taking measurements?

No, the unit features a focus-free optical system with a 50° × 38° field of view, allowing you to instantly point and measure without manual lens adjustment.

How durable is the UTi712S+ for industrial use?

The imager is engineered for demanding work environments, carrying an IP54 rating against dust and water ingress and proven to survive drops of up to 2 metres onto hard surfaces.

Technical data
Product number: 202745

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.