UNI-T UTi716B Professional Thermal Imaging Camera 160x120 (-20 to 550°C)
€260.50
Available, delivery time: 1-3 days
| Product number: | 202676 |
|---|---|
| Manufacturer number: | UTi716B |
| EAN | 6935750571613 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UTi716B Professional Thermal Imaging Camera 160x120 (-20 to 550°C)"
Main Product Features
- Infrared resolution of 160 × 120 pixels for crisp thermal diagnostics
- Wide temperature measurement range from -20 °C up to 550 °C
- High-contrast display for quick on-site evaluation and hot-spot detection
- Ergonomic handheld design engineered for daily industrial and trade use
- Multiple colour palettes to quickly visualise thermal gradients
- Comprehensive analysis capabilities for preventive maintenance
Engineered for Accurate Thermal Insights
In modern industrial facilities, electrical switchgear maintenance, and HVAC diagnostics, detecting invisible heat anomalies before system failure is essential. The UNI-T UTi716B professional thermal imaging camera bridges the gap between portability and diagnostic accuracy. By translating infrared radiation into actionable visual data, it allows engineers, electricians, and technicians to spot thermal bottlenecks in seconds.
Versatile Diagnostics Across Diverse Sectors
Whether tracing overloaded electrical circuits, spotting unbalanced phase loads, or identifying thermal leaks in building envelopes, the UTi716B delivers clear insight. In mechanical environments, it quickly highlights friction-induced heating in bearings, misalignment in shafts, and blockages in cooling circuits. This capability saves valuable maintenance hours and helps avoid catastrophic downtime.
Ergonomic Field Usability
Designed with real-world troubleshooting in mind, the camera sits comfortably in the hand, featuring an intuitive button layout that allows rapid one-handed operation. The clear colour display renders subtle temperature variations visible, allowing users to adapt to different reflective surfaces and inspection challenges on the fly. Detailed thermal images can be reviewed instantly on site, streamlining communication with clients or maintenance supervisors.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | UTi716B |
| Thermal Resolution | 160 × 120 pixels |
| Temperature Measurement Range | -20 °C to 550 °C |
| Product Category | Handheld Thermal Imaging Camera |
| Primary Applications | Electrical, Mechanical, HVAC & Building Diagnostics |
Frequently Asked Questions
What makes the UTi716B suitable for electrical maintenance?
The UTi716B offers an optimal 160 × 120 thermal resolution and a broad temperature span up to 550 °C, enabling technicians to identify hot spots, loose terminal connections, and overloaded fuses safely from a distance.
Can this thermal camera detect insulation defects in buildings?
Yes. The wide measurement range down to -20 °C and distinct thermal imaging allow users to highlight missing insulation, thermal bridging, and unwanted air infiltration around windows and doors.
Does the camera offer multiple colour palettes?
Yes, users can choose between multiple colour palettes to best suit their inspection environment, making it easy to distinguish subtle temperature differences or high-contrast anomalies.
Is the UTi716B suitable for mechanical inspections?
Absolutely. It is frequently used to monitor operating temperatures of motors, pumps, bearings, and conveyor rollers to detect premature mechanical wear.
How does the camera assist in preventive maintenance programs?
By detecting abnormal heat signatures early, maintenance teams can schedule targeted repairs before equipment fails, reducing unexpected operational downtime and maintenance costs.
| Product number: | 202676 |
|---|
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.