Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi716S Thermal Camera 160x120 -20°C to 550°C IP54

Product information "UNI-T UTi716S Thermal Camera 160x120 -20°C to 550°C IP54"

Main Product Features

  • Infrared resolution of 160 x 120 pixels for crisp thermal imaging
  • Wide temperature measurement range from -20 °C to 550 °C
  • Robust IP54-rated housing resistant to dust and splash water
  • Instant high and low temperature auto-tracking on screen
  • Clear digital visual display combined with thermal rendering
  • Ergonomic pistol-grip design for comfortable one-handed operation
  • Long-lasting rechargeable battery for demanding working days

Professional Thermal Diagnostics Made Accessible

The UNI-T UTi716S handheld thermal imaging camera delivers the ideal balance between high optical precision and everyday workshop durability. Designed to meet the demanding requirements of facility technicians, HVAC specialists, and field engineers, this imager transforms invisible thermal patterns into crystal-clear diagnostics. Whether identifying an overloaded circuit breaker, tracing faulty hydronic underfloor heating pipes, or troubleshooting mechanical bearings under stress, the UTi716S gives you immediate visual proof of thermal anomalies.

High Precision Across a Broad Temperature Range

Covering an extensive spectrum from -20 °C up to 550 °C, the UTi716S is engineered for versatile multi-industry deployments. The 160 x 120 thermal sensor captures detailed heat maps, making it straightforward to distinguish minute temperature differences across complex components. Real-time automatic cold and hot spot tracking highlights critical areas instantly, allowing you to address electrical fire hazards or structural insulation deficits before costly downtime occurs.

Ergonomic Field Companion with IP54 Durability

Industrial diagnostics rarely take place in pristine environments. With its sturdy IP54-rated construction, the UTi716S is shielded against dust ingress and water splashing, making it fully dependable on busy construction sites, damp boiler rooms, and exposed industrial floors. The intuitive trigger mechanism and balanced pistol grip guarantee fatigue-free handling during comprehensive routine inspections and continuous documentation runs.

Technical Specifications

ParameterValue
ModelUTi716S
Thermal Resolution160 x 120 pixels
Temperature Range-20 °C to 550 °C
Protection RatingIP54 (dust and splash water)
Form FactorHandheld ergonomic imager
Tracking ModesAuto High/Low Temperature Tracking

Frequently Asked Questions

What are the primary applications for the UTi716S?

The camera is primarily engineered for electrical cabinet inspections, mechanical diagnostics of motors and pumps, HVAC efficiency evaluations, and building envelope energy audits.

Does the camera handle wet or dusty environments?

Yes, the housing is rated IP54, which offers robust protection against dust intrusion and splashing water from all directions.

Can the device automatically pinpoint the hottest spot in a frame?

Yes, the UTi716S features dynamic automatic tracking that flags the highest and lowest temperatures in real-time directly on the display.

Is this camera suitable for high-temperature furnace or exhaust inspection?

With an upper temperature threshold of 550 °C, it is well suited for inspecting industrial piping, exhaust components, and moderate-temperature processing equipment.

Can I operate the camera comfortably with work gloves?

The ergonomic grip, pronounced measurement trigger, and tactile control buttons allow for reliable single-handed operation even when wearing standard protective work gloves.

Technical data
Product number: 202703

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.