Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi720A Professional Thermal Imaging Camera 256x192

Product information "UNI-T UTi720A Professional Thermal Imaging Camera 256x192"

Main Product Features

  • Crisp infrared resolution of 256 x 192 pixels for high-detail thermal images
  • Vibrant display offering intuitive visual temperature analysis in real time
  • Multiple colour palettes to suit diverse diagnostic environments and surfaces
  • High and low temperature auto-tracking for instant hotspot detection
  • Robust, ergonomic handheld housing engineered for demanding daily site inspections
  • Rechargeable battery providing extended operational runtime in the field
  • Convenient image capture and storage on MicroSD card for rapid reporting

Advanced Infrared Diagnostics with the UNI-T UTi720A

Accurate temperature assessment is critical when troubleshooting electrical enclosures, identifying building insulation defects, or inspecting industrial machinery. The UNI-T UTi720A handheld thermal imaging camera provides professionals with reliable thermographic insight. Featuring an uncooled focal plane array with a 256 x 192 infrared resolution, this diagnostic instrument captures subtle thermal variations that remain entirely invisible to the naked eye. Technicians can rapidly scan broad surface areas and pinpoint potential issues before they escalate into costly equipment failures or safety hazards.

Versatile Applications in Building and Mechanical Inspections

Whether tracing underfloor heating loops, detecting thermal bridges in facades, or assessing pipe blockages, the UTi720A offers the clarity required for decisive evaluations. For electrical contractors, the camera streamlines routine preventative maintenance: breaker panels, busbars, and cable connections can be assessed under load without direct contact. Mechanical engineers benefit from immediate visibility into overheated bearings, misaligned shafts, and worn drive belts, allowing predictive maintenance schedules to replace reactive downtime.

Designed for Ergonomic Efficiency

Fieldwork requires tools that are balanced, reliable, and straightforward to operate. The UTi720A is engineered with an intuitive trigger-operated capture system and a balanced grip that minimizes hand fatigue during prolonged surveys. Its fast refresh rate delivers smooth, fluid panning across targets, while dedicated measurement cursors display central point, maximum, and minimum temperatures simultaneously. Switch between distinct colour palettes to enhance contrast depending on whether you are assessing delicate circuit boards or expansive roof sections.

ParameterSpecification
IR Resolution256 x 192 pixels
Device TypeHandheld thermal imaging camera
Temperature TrackingAuto high/low and center spot tracking
Display ModesThermal view with selectable colour palettes
Data StorageMicroSD card slot
Power SupplyRechargeable lithium battery pack
Form FactorErgonomic pistol grip

Frequently Asked Questions

What type of maintenance is the UTi720A best suited for?

The UTi720A is ideally designed for electrical panel monitoring, HVAC system balancing, mechanical drive diagnostics, and building envelope surveys to locate heat leaks and moisture accumulation.

Can the captured images be exported for client reporting?

Yes, captured thermal images are stored directly onto a removable MicroSD card, allowing straightforward transfer to a PC for inspection reports and customer documentation.

How does the auto-tracking function work?

The camera automatically detects and tracks the highest and lowest temperature points within the active field of view, displaying their precise coordinates and temperature values dynamically on screen.

Are multiple colour palettes available on the device?

Yes, the camera includes several visual palettes such as Ironbow, Rainbow, and White Hot, allowing operators to choose the best contrast level for specific inspection tasks.

Is this camera suitable for outdoor inspections?

Yes, its portable design and durable casing make it well-suited for both indoor plant maintenance and outdoor building diagnostics.

Technical data
Product number: 202657

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.