Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi720E Thermal Camera 256x192 -20 to 550°C Wi-Fi

Product information "UNI-T UTi720E Thermal Camera 256x192 -20 to 550°C Wi-Fi"

Main Product Features

  • High-resolution infrared sensor with 256x192 pixels for crisp diagnostic clarity
  • Wide temperature measurement range from -20°C up to 550°C
  • Integrated Wi-Fi connectivity for fast data transfer and wireless analysis
  • Versatile image modes including thermal, visible light, blending, and picture-in-picture
  • Intuitive high-resolution touchscreen display for streamlined onsite operation
  • Rechargeable high-capacity battery for extended professional field work
  • USB interface for PC connectivity, direct reporting, and real-time screen projection

Professional Thermal Diagnostics with the UNI-T UTi720E

In demanding maintenance, electrical troubleshooting, and building survey environments, accuracy and efficiency are paramount. The UNI-T UTi720E thermal imaging camera stands as a high-precision instrument engineered to locate invisible problems in seconds. Combining an IR resolution of 256x192 with an extended thermal detection range spanning from -20°C to 550°C, this device provides the analytical depth required by technicians, facility managers, and energy auditors alike.

High Precision Across Industrial and HVAC Applications

Finding faulty components before catastrophic failure saves both time and significant cost. The UTi720E excels in electrical switchboard reviews, identifying overloaded circuits, loose electrical connections, and unbalanced loads. In mechanical and plant maintenance, technicians can effortlessly track overheated bearings, motor winding issues, and friction-induced wear. For HVAC specialists and building contractors, the camera highlights insulation voids, thermal bridging, air infiltration, and pipe blockages with exceptional clarity.

Enhanced Imaging Modes and Workflow Integration

Equipped with a digital visual camera alongside its thermal sensor, the UTi720E provides advanced image blending options. Users can choose between standard thermograms, pure visible spectrum photos, Picture-in-Picture (PiP), and dual-light fusion to pinpoint exact component locations against ambient backgrounds. The onboard Wi-Fi connection enables seamless communication with mobile devices and laptops, speeding up workflow by allowing instant documentation directly from the job site.

ParameterSpecification
IR Resolution256 × 192 pixels
Temperature Measurement Range-20°C to 550°C
ConnectivityWi-Fi, USB Type-C
DisplayLCD Touchscreen
Image ModesThermal, Visual, Fusion, Picture-in-Picture
Data StorageRemovable MicroSD card
Color PalettesMultiple selectable palettes

Frequently Asked Questions

What makes the UTi720E suitable for electrical maintenance?

The 256x192 IR resolution and broad -20°C to 550°C temperature range allow technicians to safely identify hot spots, faulty breakers, and thermal anomalies from a comfortable working distance.

Can I stream or share images wirelessly?

Yes, thanks to its integrated Wi-Fi functionality, you can easily connect the camera to compatible devices for swift data sharing and review on site.

How does the image blending mode work?

The camera blends thermal data with visible light details captured by the integrated optical lens, providing clear outlines and context to locate targets precisely.

Can thermal images be evaluated on a computer?

Yes, images can be transferred via USB or memory card to a PC, allowing for deeper thermal evaluation and comprehensive reporting with dedicated analysis software.

Is the UTi720E capable of detecting underfloor heating leaks?

Yes, due to its thermal sensitivity and resolution, it effectively tracks warm water pipes under floors and locates blockages or leaks without invasive inspection.

Technical data
Product number: 202705

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.
Skip product gallery

UTi720E Spare Parts

uni-t-ut-m17-replacement-spare-battery-ersatz-akku-batterie-uti720-uti730
UT-M17 Replacement Battery, UTi730, UTi720
  • Product num. : 202650
  • EAN: 6935750517185
  • Manufacturer number: UT-M17
Quantity
Unit price
  • To 4
    €75.00
  • To 9
    €71.25
    -5 %
  • From 10
    €69.00
    -8 %

Currently not available (delivery time on request)