Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UNI-T UTi720M Smartphone Thermal Camera for Android 256x192 IR

Product information "UNI-T UTi720M Smartphone Thermal Camera for Android 256x192 IR"

Main Product Features

  • Crisp 256×192 IR thermal resolution for sharp image clarity and precise diagnostic analysis
  • Wide temperature measurement range from −20 °C up to 200 °C for diverse applications
  • Direct plug-and-play USB Type-C interface tailored for modern Android smartphones and tablets
  • Multiple colour palettes and measurement modes including point, line, and regional analysis
  • Ultra-compact, lightweight, and pocket-friendly aluminium-alloy construction
  • Direct photo and video recording via the dedicated mobile companion application

Turn Your Smartphone into a Professional Thermal Imaging Tool

The UNI-T UTi720M is a high-performance thermal imaging camera designed to transform your existing Android smartphone into an advanced diagnostic instrument. Engineered for professionals, technicians, and discerning DIY enthusiasts, it combines compact portability with impressive thermal precision. By utilising the computing power and high-resolution screen of your mobile device, the UTi720M eliminates the need for bulky handheld cameras while delivering sharp 256×192 thermal imagery that reveals hidden thermal anomalies in seconds.

Precision Diagnostics at Your Fingertips

Whether you are inspecting complex electrical panels, troubleshooting underfloor heating leaks, or testing printed circuit boards (PCBs) for overheating micro-components, the UTi720M provides clear, actionable visual data. The high thermal resolution allows you to distinguish minute temperature differentials across target surfaces, ensuring problems are identified before they escalate into costly failures. Its broad −20 °C to 200 °C measurement envelope covers the majority of domestic, commercial, and electronic troubleshooting scenarios with ease.

Intuitive Android Integration and Mobile Workflow

Operating the camera is straightforward and seamless. Simply plug the module into your phone's USB-C port, launch the dedicated app, and start scanning immediately. The software suite provides real-time temperature tracking, custom emissivity controls, temperature alarms, and versatile analysis tools such as spot, area, and line measurements. Captured thermal photographs and radiometric video footage can be saved instantly to your mobile gallery, making it effortless to generate client reports, share data with team members, or document project milestones directly from the job site.

Built for Tough Everyday Use

Despite weighing only a few grams, the UTi720M features a sturdy enclosure engineered to withstand everyday handling in demanding working environments. Its tiny form factor allows it to slip effortlessly into a tool vest, pocket, or protective case, ensuring professional thermography capabilities are always within arm's reach wherever duty calls.

Technical Specifications

Thermal Resolution256 × 192 pixels
Temperature Measurement Range−20 °C to 200 °C
Connection InterfaceUSB Type-C
Operating SystemAndroid
Measurement ModesPoint, Line, Area (High/Low tracking)
Image / Video CaptureSupported via mobile app
Form FactorUltra-compact plug-in module

Frequently Asked Questions

Does the UTi720M require an internal battery?

No, the camera does not contain an internal battery. It draws minimal power directly from your smartphone via the USB-C connection, meaning you never have to worry about charging an additional device before a job.

Can I use this device on an Apple iOS device?

No, the UTi720M is designed specifically for Android smartphones and tablets equipped with a USB Type-C port and OTG support.

Is the camera suitable for diagnosing electrical switchboards?

Yes, the 256×192 resolution makes it well suited for identifying loose connections, overloaded circuits, and unbalanced phases in domestic and industrial electrical panels.

Do I need an active internet connection to operate the camera?

No, after downloading the dedicated application, the camera operates entirely offline without requiring network access or cloud subscriptions.

Can I adjust the emissivity settings in the app?

Yes, the companion app allows you to adjust surface emissivity to ensure accurate temperature measurements across different materials such as metals, plastics, and building surfaces.

Technical data
Product number: 202706

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.