UNI-T UTi721M Smartphone Thermal Camera 256x192 USB-C
| Quantity | Unit price |
|---|---|
| To 4 |
€180.66
|
| To 9 |
€265.05
|
| To 24 |
€251.10
|
| From 25 |
€223.20
|
Available, delivery time: 1-3 days
| Product number: | 202643 |
|---|---|
| Manufacturer number: | UTi721M |
| EAN | 5901890095266 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UTi721M Smartphone Thermal Camera 256x192 USB-C"
Main Product Features
- Crisp 256x192 infrared sensor resolution capturing fine thermal details
- Wide temperature measurement span from -20°C to 550°C (-4°F to 1022°F)
- Smooth 25 Hz refresh rate for real-time inspection without stutter
- High thermal sensitivity with NETD ≤50 mK detecting minute temperature differences
- Broad 56.0° x 42.2° field of view with focus-free operation
- Three display modes: Thermal, Fusion, and Picture-in-Picture (PIP)
- Seven colour palettes including Ironbow, Rainbow, Lava, and Black hot
- Comprehensive on-screen analysis supporting 3 points, 3 lines, and 3 rectangles
- Direct USB Type-C connection for Android 6.0 and above via Google Play app
- Rugged and compact build rated for 1-metre drop protection
Professional Thermal Diagnostics Directly on Your Android Device
The UNI-T UTi721M thermal imaging camera transforms your Android smartphone or tablet into a powerful diagnostic tool. Designed for trade professionals, field service technicians, building contractors, and discerning DIY enthusiasts, this compact accessory plugs straight into your device via USB Type-C. Boasting a high-definition 256x192 infrared sensor and a rapid 25 Hz frame rate, the UTi721M displays smooth, live thermal imagery without noticeable lag, allowing you to identify thermal bridges, electrical hotspots, and HVAC inefficiencies instantly.
Versatile Dual-Mode Measurement
Whether examining mechanical gearboxes or scanning for elevated body temperatures, the UTi721M features dedicated operational modes to match the task. In Industry mode, the camera measures temperatures ranging from -20°C up to 550°C with an accuracy of ±2°C or ±2%. For human surface temperature monitoring, the Elevated Skin Temperature (EST) mode narrows the range to 30°C–40°C with a heightened accuracy of ±0.5°C, providing quick non-contact screening wherever required.
Advanced Image Processing and Multi-Point Analysis
Equipped with seven selectable colour palettes (White hot, Lava, Ironbow, Black hot, Red hot, Rainbow, and Rainbow HC), the camera lets you tailor visual contrast to any inspection scenario. Enhance contextual awareness using Image Fusion or Picture-in-Picture (PIP) modes to overlay infrared diagnostics directly on physical surroundings. With extensive on-screen analysis tools—including simultaneous tracking across 3 points, 3 lines, and 3 custom rectangles—as well as high/low temperature alarms and automated isotherms, locating anomalies becomes intuitive and accurate.
Effortless Documentation and Mobile Convenience
Through the dedicated Android application available on Google Play, users can record high-resolution photos and video sequences directly to smartphone storage. Built-in analysis functions allow you to rotate images, apply custom brush overlays, and conduct post-capture thermal reviews on-site before sharing reports directly with clients or colleagues. Engineered to endure tough job site conditions, the lightweight housing survives drops from up to 1 metre.
Technical Specifications
| Parameter | Specification |
|---|---|
| IR Resolution | 256 × 192 pixels |
| Pixel Size | 12 µm |
| Thermal Sensitivity (NETD) | ≤ 50 mK |
| Frame Rate | ≤ 25 Hz |
| Field of View (FOV) | 56.0° × 42.2° |
| Spatial Resolution (IFOV) | 3.8 mrad |
| Focal Length | 3.2 mm |
| Focus Mechanism | Focus free |
| Temperature Measurement Range | -20°C to 550°C (-4°F to 1022°F) |
| Measurement Accuracy | Industry: ±2°C or ±2% (0°C to 550°C); EST: ±0.5°C (30°C to 40°C) |
| Measurement Modes | Industry & EST (Elevated Skin Temperature) |
| Image Modes | Thermal, Fusion, PIP |
| Colour Palettes | 7 (White hot, Lava, Ironbow, Black hot, Red hot, Rainbow, Rainbow HC) |
| On-Screen Analysis | 3 Points, 3 Lines, 3 Rectangles |
| Isotherm | Auto / Manual |
| Alarms | High / Low temperature alarm |
| Media Capture | Photo capturing & Video recording |
| Interface | USB Type-C |
| Smartphone Compatibility | Android 6.0 and higher |
| Drop Resistance | 1 metre |
Frequently Asked Questions
Which mobile operating systems are compatible with the UTi721M?
The UTi721M requires a smartphone or tablet running Android 6.0 or higher equipped with a USB Type-C port. The companion analysis software is easily downloaded via Google Play.
What is the difference between Industry mode and EST mode?
Industry mode provides a wide measurement range of -20°C to 550°C with an accuracy of ±2°C or ±2% for mechanical, electrical, and building checks. EST (Elevated Skin Temperature) mode optimizes accuracy to ±0.5°C across 30°C to 40°C for fast preliminary body temperature scanning.
Can I record thermal video as well as capture still photos?
Yes, the companion application allows you to capture still thermal images as well as record continuous video footage at up to 25 Hz directly onto your phone.
Does the camera require manual focusing?
No, the UTi721M uses a focus-free optical system with a 3.2 mm focal length, providing crisp images across practical working distances without needing manual adjustments.
How durable is the camera during everyday field work?
The device is built for trade use and field diagnostics, featuring a durable construction rated for drop resistance from heights up to 1 metre.
| Product number: | 202643 |
|---|
| Flyer: | Product%20Flyer--UTi721M.pdf?ts=1795083799 |
|---|---|
| Manual: | UTi720MUTi721M_User-Manual_DE.pdf?ts=1795083809 |
| Other documents: | UTi720MUTi721M_User-Manual_EN.pdf?ts=1795083845 |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.