UNI-T UTi722M Smartphone Thermal Camera for Android 256x192 IR
€239.49
Available, delivery time: 1-3 days
| Product number: | 202747 |
|---|---|
| Manufacturer number: | UTi722M |
| EAN | 6935750572207 |
Are you a reseller, need a large quantity or have a price target?
Apply for a reseller / high volume account to get access to our wholesale conditions. You can also contact our sales team at any time via info@schwick.de or +49 2191 598 280
Product information "UNI-T UTi722M Smartphone Thermal Camera for Android 256x192 IR"
Main Product Features
- Crisp 256 x 192 infrared resolution with 12 µm pixel pitch and ≤50 mK thermal sensitivity
- Manual focus 4.0 mm lens for razor-sharp thermal images from close-up components to distant targets
- Wide temperature measurement range from -20°C up to 450°C for versatile industrial testing
- Dual operating modes: Industrial inspection and elevated skin temperature (EST) screening
- Direct plug-and-play USB Type-C operation without onboard battery, powered by your Android smartphone
- Ultra-compact and rugged aluminium alloy housing weighing only approximately 30 g with 1 m drop resistance
- Comprehensive analysis via the 'Thermal Mobile' app with photo and MP4 video recording
- 7 colour palettes: White hot, Lava, Ironbow, Black hot, Red hot, Rainbow, and Rainbow HC
Professional Thermal Diagnostics Directly on Your Android Device
The UNI-T UTi722M turns any compatible Android smartphone into a high-performance infrared imaging system. Designed for professionals and technical experts who require immediate thermal diagnostics without carrying bulky standalone equipment, this pocket-sized thermal camera delivers pristine thermal clarity on the go. Its rugged aluminium alloy enclosure ensures durability in tough job-site environments while keeping the total weight at a negligible 30 grams.
High Precision Imaging with Manual Focus Control
Unlike fixed-focus smartphone thermal accessories that struggle with macro work or distant objects, the UTi722M features a 4.0 mm manual-focus lens. Combined with a detailed 256 x 192 detector and high thermal sensitivity (NETD ≤50 mK), it gives you pinpoint sharpness across a wide range of focal distances. Whether you are inspecting tiny surface-mount electronics on a printed circuit board or surveying an entire electrical distribution cabinet, you can dial in the focus to capture precise temperature gradients and fine details.
Versatile Dual-Mode Functionality: Industry and EST Screening
The UTi722M adapts seamlessly to your operational requirements with two dedicated measurement modes. In Industry Mode, the camera tackles complex predictive maintenance across a wide range spanning -20°C to 450°C with an accuracy of ±2°C or ±2%. In EST screening mode, the sensor narrows its calibration to 30°C to 40°C with an enhanced precision of ±0.5°C, making it a reliable diagnostic tool for quick preliminary human surface temperature checks.
Practical Applications Across Trades
HVAC technicians can quickly identify blocked radiators, monitor underfloor heating pipe layouts, and locate refrigerant leaks. Electrical contractors and facility managers can spot overloaded circuit breakers, loose terminal connections, and unbalanced loads before costly downtime occurs. Furthermore, building inspectors can assess structural thermal bridges, draft air infiltration, and hidden moisture accumulation inside walls and ceilings with confidence.
Effortless Operation with the 'Thermal Mobile' App
Operating completely battery-free, the camera draws minimal power directly through its USB Type-C connector, eliminating downtime associated with internal battery degradation or forgotten charging cables. Through the intuitive 'Thermal Mobile' application, users can capture high-resolution JPEG stills and MP4 video recordings, adjust emissivity, switch between 7 distinct colour palettes, and instantly export documentation directly to colleagues or clients from the field.
Technical Specifications
| Parameter | Specification |
|---|---|
| IR Resolution | 256 x 192 pixels |
| Pixel Pitch | 12 µm |
| Thermal Sensitivity (NETD) | ≤50 mK |
| Frame Rate | ≤25 Hz |
| Lens Focal Length | 4.0 mm |
| Focus Mechanism | Manual focus |
| Field of View (FOV) | 44.92° (H) x 33.42° (V) |
| Spatial Resolution (IFOV) | 3.0 mrad |
| Temperature Measurement Range | -20°C to 450°C |
| Industry Accuracy | ±2°C or ±2% (whichever is greater, 0°C to 450°C) |
| EST Accuracy | ±0.5°C (30°C to 40°C) |
| Measurement Modes | Industry, EST screening |
| Colour Palettes | White hot, Lava, Ironbow, Black hot, Red hot, Rainbow, Rainbow HC |
| Image & Video Formats | JPEG, MP4 |
| Interface | USB Type-C |
| Drop Proof | 1 m |
| Dimensions | 29.5 x 24.5 x 29.5 mm |
| Weight | Approx. 30 g |
| Housing Material | Aluminium alloy |
Frequently Asked Questions
Does the UNI-T UTi722M require an internal battery to operate?
No, the UTi722M is completely battery-free. It draws a small amount of power directly from your Android smartphone via the USB Type-C port, ensuring it is always ready to use whenever you need it.
What are the benefits of the manual focus lens?
The manual focus mechanism allows you to bring objects into sharp focus at varying distances. This is especially useful for close-up inspections such as PCB circuit analysis, as well as mid-range checks on electrical cabinets or building facades where fixed-focus lenses lose clarity.
Which operating system and app are needed to use this thermal camera?
The camera is designed for Android smartphones equipped with a USB Type-C port supporting OTG functionality. It is operated through the official 'Thermal Mobile' application available for download.
Can the UTi722M record videos as well as photos?
Yes, the camera supports both still photography in JPEG format and dynamic thermal video recording in MP4 format directly onto your mobile phone storage.
What is the difference between Industry and EST screening modes?
Industry Mode measures a broad range from -20°C to 450°C with an accuracy of ±2°C or ±2% for mechanical, electrical, and HVAC tasks. EST screening mode focuses specifically on 30°C to 40°C with higher precision (±0.5°C) to detect surface body temperature deviations.
| Product number: | 202747 |
|---|
| Flyer: | UTi722M%20Data%20Sheet.pdf?ts=1795018710 |
|---|---|
| Manual: | UTi722M_User-Manual_DE.pdf?ts=1795018722 |
| Other documents: | UTi722M_User-Manual_EN.pdf?ts=1795018763 |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.