Product information "UT202BT UNI-T Smart Clamp Meter 600A AC True RMS Bluetooth"

Main Product Features

  • True RMS measurement for AC current up to 600 A and AC/DC voltage up to 600 V
  • Integrated Bluetooth interface for real-time data transmission to a mobile app
  • Dual display with 9999 counts resolution and bright backlighting
  • Low-Pass Filter (LPF) for stable measurements on variable-frequency signals
  • Inrush current capture and Peak Hold memory function
  • Capacitance measurement up to 100 mF, resistance, frequency, and temperature testing
  • Non-Contact Voltage (NCV) detection with integrated flashlight
  • Safety rating according to CAT III 600 V with double insulation
  • Jaw opening width of 28 mm for non-invasive cable measurements

Field Diagnostics for Commercial and Industrial Systems

The UNI-T UT202BT clamp meter is designed for electrical installers, facility managers, and service technicians working in plant engineering, commercial maintenance, and building infrastructure. Rated for CAT III 600 V environments with double insulation and pollution degree II, the instrument is suited for testing stationary electrical panels, distribution boards, and branch circuits.

Signal Analysis, Inrush Current, and Filtering

Equipped with a 28 mm jaw opening, the clamp non-invasively encloses conductors to measure AC current up to 600 A. True RMS processing provides accurate readings on non-sinusoidal waveforms. An inrush current capture function and Peak Hold memory enable users to monitor high transient peaks during motor startups and inductive load switching.

When measuring variable-frequency drives and motor controllers, the selectable Low-Pass Filter (LPF) suppresses high-frequency electrical noise. In addition to AC current, the instrument tests AC/DC voltages up to 600 V, resistance, frequency, temperature, continuity, and capacitances up to 100 mF.

Ergonomic Operation and Wireless Connectivity

Designed for straightforward one-handed operation via push buttons, the instrument features a 9999-count dual display capable of showing simultaneous parameters such as voltage with frequency (V+Hz) or current with frequency (A+Hz). A display backlight and built-in flashlight assist work inside poorly lit distribution cabinets.

Live measurement data can be streamed via integrated Bluetooth to a compatible smartphone app for convenient logging and remote monitoring. Safety is supported by an integrated Non-Contact Voltage (NCV) sensor and an over-temperature warning that triggers when the clamp jaw exceeds 80 °C. The unit is powered by two 1.5 V AAA batteries.

ModelUT202BT
ManufacturerUNI-T
Display Counts9999 counts (Dual Display)
AC CurrentUp to 600 A
AC/DC VoltageUp to 600 V
Capacitance RangeUp to 100 mF
Measurement MethodTrue RMS
FunctionsInrush current, LPF, Peak Hold, NCV, Diode/Continuity, Resistance, Frequency, Temperature
Jaw Opening28 mm
Measurement CategoryCAT III 600 V
Pollution DegreeII
InsulationDouble insulation
Applied StandardsEN 61326-1, EN 61326-2-2
Over-Temperature WarningTriggered above 80 °C at the clamp jaw
Power Supply2 x 1.5 V AAA batteries

FAQ

How are measurement data transmitted wirelessly?

The UT202BT features an integrated Bluetooth module that transmits live measurement data directly to a mobile application on a smartphone or tablet.

What is the purpose of the Low-Pass Filter (LPF)?

The LPF function suppresses high-frequency noise and interference, enabling more stable voltage and current measurements on variable-frequency drives and motor controllers.

What is the maximum jaw opening of the clamp meter?

The clamp jaws open up to 28 mm, allowing conductors to be enclosed without disconnecting the circuit.

Which safety category is the device rated for?

The instrument meets measurement category CAT III 600 V with double insulation and pollution degree II.

Does the UT202BT detect live cables without direct contact?

Yes, the clamp meter includes an integrated Non-Contact Voltage (NCV) sensor for identifying AC voltage fields without test leads.

Technical data
Product number: 202679

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280