Product information "UT208B UNI-T True RMS Digital Clamp Meter 1000A AC/DC"
Main Product Features
- True RMS current measurement for AC and DC up to 1000 A (extendable to 3000 A with optional flexible probe)
- AC and DC voltage measurement up to 1000 V
- Inrush current capture mode for recording transient start-up currents
- Low-pass filter (LPF ACV) for accurate measurements on variable frequency drives (VFD) and inverters
- LoZ mode to suppress ghost and phantom voltages
- Temperature measurement from -40 °C to 1000 °C with 0.1 °C resolution
- Non-contact voltage detection (NCV) with multi-segment display and visual/audible alert
- Large 6000-count LCD with 31-segment analogue bargraph and automatic backlight
- Measurement categories CAT III 1000 V and CAT IV 600 V
- Large jaw opening of 42 mm for conductors of various cross-sections
Reliable Electrical Diagnostics in Industrial Installations
The UNI-T UT208B True RMS digital clamp meter is tailored for electricians, industrial technicians, and facility maintenance engineers. Rated for CAT III 1000 V and CAT IV 600 V environments, it handles inspections on switchboards, main distribution panels, and supply points. Its 42 mm jaw opening accepts substantial conductor cross-sections, enabling non-intrusive current measurements up to 1000 A in both AC and DC systems. If higher ranges are required, the AC capability can be expanded to 3000 A using an optional flexible current probe.
Dedicated Modes for Drives and Dynamic Loads
For troubleshooting modern motor control circuits, the built-in low-pass filter (LPF ACV) suppresses high-frequency noise typically generated by variable frequency drives and inverters. The LoZ mode utilizes a lowered input impedance to discharge and eliminate ghost voltages caused by capacitive coupling on adjacent lines. In addition, the integrated inrush mode captures transient peak currents up to 1000 A during the initial start-up phase of motors and heavy electrical machinery.
Comprehensive Testing and Temperature Monitoring
Beyond current and voltage, the instrument serves as a fully featured testing device, measuring resistance up to 60 MΩ, capacitance up to 60 mF, frequency up to 1 MHz, and duty cycle between 10% and 90%. Continuity checks with a buzzer and diode testing simplify circuit evaluation. Contact temperature monitoring across a range of -40 °C to 1000 °C with 0.1 °C resolution is supported via the included point contact temperature probe.
Clear Readouts and Practical Features
The illuminated 6000-count screen incorporates a 31-segment analogue bargraph for tracking signal trends. A dedicated DC Zero mode provides reliable zero-offset adjustment for direct current measurements, complemented by Data Hold, Relative mode, and MAX/MIN tracking. Operators can check for active AC voltage without direct contact through the integrated NCV sensor with visual and audible feedback. A built-in LED flashlight aids work in dim cabinets, and an automatic shut-off function with under 50 µA standby current preserves the three AAA power cells.
| Model | UNI-T UT208B |
| Display Count | 6000 counts (with 31-segment analogue bar) |
| AC Current Range | 1000 A (±2% + 5) |
| DC Current Range | 1000 A (±2% + 5) |
| AC Current Frequency Response | 40 Hz to 400 Hz |
| Inrush Current Range | 1000 A (±10% + 10) |
| AC Voltage Range | 6 V to 1000 V (up to ±1% + 8) |
| DC Voltage Range | 600 mV to 1000 V (up to ±0.5% + 5) |
| LoZ ACV Range | 600 V / 1000 V (±2% + 5) |
| Low Pass Filter (LPF ACV) | 600 V / 1000 V (±2% + 5) |
| Resistance Range | 600 Ω to 60 MΩ (up to ±2% + 8) |
| Capacitance Range | 60 nF to 60 mF (up to ±10% + 9) |
| Frequency Range | 10 Hz to 1 MHz (±0.1% + 3) |
| Duty Cycle | 10% to 90% (±2.6% + 7) |
| Temperature Range | -40 °C to 1000 °C (up to ±1% + 2) |
| Jaw Opening | 42 mm |
| Input Impedance (ACV/DCV) | ≥10 MΩ |
| Safety Rating | CAT III 1000 V / CAT IV 600 V |
| Power Supply | 3x 1.5 V battery (AAA / R03) |
| Dimensions | 272 mm x 81 mm x 43.5 mm |
| Net Weight | 420 g |
Frequently Asked Questions
Can the UT208B measure direct current (DC) via the clamp?
Yes, the clamp jaws measure both AC and DC current up to 1000 A, including a zeroing function for DC offsets.
What is the benefit of the LPF ACV function?
The low-pass filter suppresses high-frequency noise from variable frequency drives and inverters, delivering steady and accurate AC voltage readings.
Can the current measurement range be expanded?
The AC current range can be extended up to 3000 A using an optional flexible current probe.
How does the NCV function indicate active voltage?
Non-contact voltage detection signals the presence of electrical fields through a multi-segment LCD bar and an integrated visual and audible alarm.
What is the purpose of the LoZ mode?
LoZ presents a low input impedance to eliminate stray or ghost voltages induced in unenergized parallel wiring.
| Product number: | 202561 |
|---|---|
| Size: | 272mm x 81mm x 43.5mm |
| Weight: | 0.42kg |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280