Main Product Features
- Negative corona sensor with a maximum detection sensitivity of 3g/a
- Broad gas detection compatible with CFCs, HCFCs, and HFCs
- 6 selectable sensitivity levels for targeted adaptation to ambient conditions
- Dual alarm system combining an audible buzzer and a 6-level visual LED indicator
- Fast warm-up time of approximately 3 seconds after power-on
- Operating time of up to 20 hours powered by 4 AA alkaline batteries
- Power-on auto-reset and manual zero reset functions for zero-point calibration
- Acoustic mute mode and integrated auto power-off function
- Flexible probe rod with replaceable sensor tip and roughly 50 hours probe life
Leak Localization Across HVAC and Automotive Systems
The UNI-T UT336A enables technicians and maintenance specialists to pinpoint leaks in commercial refrigeration systems, stationary air conditioning units, chillers, and automotive climate circuits. Equipped with a flexible probe neck, the device accesses narrow valve assemblies, pipe joints, and evaporator coils. The negative corona sensor reacts across major halogenated gas families, detecting CFCs such as R11 and R12, HCFCs such as R22 and R141, and HFCs including R134a, R410a, and R500 down to leakage rates of 3 g/year.
Rapid Start-Up and Background Gas Calibration
The electronic sensor reaches operational readiness within approximately 3 seconds after activation. In environments containing ambient refrigerant vapours, the sensitivity can be adapted through 6 selectable stages. Supplemented by the zero-reset function, the instrument establishes a baseline against current atmospheric contamination, permitting targeted tracking of the primary release source without false triggers.
Dual-Alert Indication and Practical Operation
When halogens interact with the sensor tip, the device issues synchronized optical and audible signals. A 6-segment LED bar graph indicates signal strength alongside an internal buzzer whose pulse frequency increases near the leak point. The acoustic indicator can be muted via a dedicated key when working in noise-sensitive settings. An automatic power-off routine engages during periods of inactivity to conserve the capacity of the AA battery cells.
| Model | UT336A |
| Sensor Technology | Negative Corona Sensor |
| Maximum Sensitivity | 3g/a |
| Warm-Up Time | approx. 3 seconds |
| Sensitivity Levels | 6 levels, adjustable |
| Alarm Indications | Audible buzzer and 6-level LED indicator |
| Compatible Refrigerants | CFCs, HCFCs, HFCs (e.g., R12, R22, R134a, R410a) |
| Probe Service Life | approx. 50 hours (normal detection conditions) |
| Power Supply | 4x AA alkaline batteries |
| Battery Operating Life | approx. 20 hours |
| Automatic Power-Off | Yes |
| Zero Reset Function | Yes |
| Mute Function | Yes |
| Operating Temperature | 0°C to 50°C |
| Operating Humidity | <95% RH (non-condensing) |
| Dimensions | 190 x 65 x 43 mm (excluding probe rod) |
| Product Net Weight | 312 g (excluding batteries) |
Frequently Asked Questions
Which refrigerants can the UNI-T UT336A detect?
The device detects all common halogenated refrigerant types, including chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs), and hydrofluorocarbons (HFCs) such as R134a, R22, R410a, and R12.
How does the negative corona sensor function?
The sensor generates a negative corona field at its tip; when halogen-containing gas enters the field, electron flow is altered, triggering the audible and visual alarms.
How can background refrigerant concentrations be handled?
Operators can reduce the sensitivity across 6 selectable levels or press the reset button to recalibrate the zero baseline to the current ambient level.
What is the typical lifespan of the sensor probe?
The sensor probe delivers an operational lifespan of approximately 50 hours under normal detection conditions and can be swapped with the included auxiliary spare probe.
| Product number: | 202715 |
|---|
| Flyer: | ut336a-datenblatt-data-sheet.pdf |
|---|---|
| Manual: | UT336A Anleitung Deutsch.pdf |
| Other documents: | UT336A User Manual English.pdf |
Manufacturer
Company Name
Uni-Trend Technology (China) Co., Ltd.
Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN
Phone
(+86-769)85723888
EU Responsible Person
Company Name
P+C Schwick GmbH
Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany
E-Mail
info@schwick.de
Phone
+492191598280
Safety Instructions
⚠️ Safety and Warning Instructions for Measurement and Testing Equipment
Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:
Electrical Safety & Voltage Hazards (Danger to Life)
- Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
- Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
- Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
- Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
- Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).
Laser Radiation & Optical Hazards
- Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
- Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
- Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.
Heat, fire hazard & environmental conditions
- Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
- Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
- Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.
Mechanical hazards & handling
- Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
- Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
- Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.
General Information & Health
- Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
- Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
- Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.