Skip to main content Skip to search Skip to main navigation
Contact us: Email: info@schwick.de Phone: +49 2191 598 280; Please note: We can only deliver to businesses or educational institutions.

UTD2102CEX+ UNI-T Digital Oscilloscope 100 MHz 2 Channels

Product information "UTD2102CEX+ UNI-T Digital Oscilloscope 100 MHz 2 Channels"

Main Product Features

  • 100 MHz bandwidth across 2 analog input channels
  • Real-time sampling rate of 1 GSa/s
  • Memory depth of 64 kpts for detailed waveform analysis
  • Waveform capture rate of 5,000 wfms/s
  • Rise time of less than 3.5 ns
  • Wide vertical sensitivity range from 1 mV/div to 20 V/div
  • Large 7-inch WVGA TFT LCD display with 800×480 resolution
  • 34 automated parameter measurements with simultaneous display of 5 values
  • Integrated mathematical operations: +, -, ×, ÷, and FFT
  • USB Host and USB Device interfaces for storage, firmware updates, and PC connectivity

Signal Analysis in Laboratories, Workshops, and Education

The UNI-T UTD2102CEX+ digital storage oscilloscope provides versatile signal testing capabilities across educational settings, circuit design labs, and maintenance environments. Offering two channels with 100 MHz bandwidth, it serves technicians and engineers testing communication hardware, automotive electronics, and consumer devices. A fast rise time below 3.5 ns supports the reliable evaluation of rapid edge transitions in digital circuits.

Acquisition Performance and Screen Presentation

Operating with a real-time sampling rate of 1 GSa/s and a 64 kpts memory depth, the instrument preserves waveform details across diverse time settings. Waveforms appear on a 7-inch TFT LCD with 800 × 480 resolution, supporting Y-T, X-Y, and Roll display modes. Vertical sensitivity spans from 1 mV/div to 20 V/div with 8-bit vertical resolution, allowing precise scaling for both small sensor signals and power circuit lines.

Versatile Triggering and Mathematical Capabilities

Engineers can isolate complex signals using trigger options including edge, pulse width, slope, video, and alternate modes. The oscilloscope features 34 automated measurement parameters, allowing simultaneous monitoring of up to five values on screen. In addition to a built-in 6-bit hardware frequency counter, mathematical functions include addition, subtraction, multiplication, division, and FFT spectral analysis for troubleshooting frequency components.

Connectivity, Mass Storage, and Test Automation

A front-panel USB Host interface simplifies exporting waveform captures, setup configurations, and screen bitmaps directly to flash drives. The rear USB Device connection enables remote control and data transfer to a PC for logging and documentation. For repetitive test routines on production lines, an integrated Pass/Fail output terminal delivers trigger output signals based on user-defined limits.

ModelUTD2102CEX+
Bandwidth100 MHz
Analog Channels2
Real-Time Sampling Rate1 GSa/s
Memory Depth64 kpts
Waveform Capture Rate5,000 wfms/s
Rise Time< 3.5 ns
Vertical Scale1 mV/div to 20 V/div
Vertical Resolution8 bit
Time Base Scale2 ns/div to 50 s/div
Time Base ModesY-T, X-Y, Roll
Input Impedance1 MΩ ± 2%, 18 ± 3 pF
Input CouplingDC, AC, GND
Trigger TypesEdge, pulse, alternate, slope, video
Math Operations+, -, ×, ÷, FFT
Frequency Counter6 bits
Display7-inch TFT LCD (800 × 480)
InterfacesUSB Host, USB Device, Pass/Fail & Trig out
Power Supply100–240 V AC, 45–440 Hz
Dimensions (W × H × D)306 mm × 138 mm × 124 mm
Net Weight2.5 kg

FAQ

What is the sampling rate of the UTD2102CEX+?

The UTD2102CEX+ provides a real-time sampling rate of 1 GSa/s.

Can screenshots and waveforms be transferred to a computer?

Yes, waveform data, setups, and bitmap screenshots can be exported via the USB Host port to a flash drive or transmitted via the USB Device port directly to a computer.

What is the difference between the CEX+ and CL+ series?

The CEX+ series features a real-time sampling rate of 1.0 GSa/s, compared to 500 MSa/s on the CL+ models.

What probes are included with the unit?

The oscilloscope includes two UT-P04 passive probes rated for 100 MHz with switchable 1x/10x attenuation.

Does the device provide automated signal measurements?

Yes, it supports 34 automated parameter measurements and can display up to 5 measurements simultaneously on the screen.

Technical data
Product number: 202691

Manufacturer

Company Name
Uni-Trend Technology (China) Co., Ltd.

Address
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, 523 808, CN

Phone
(+86-769)85723888

EU Responsible Person

Company Name
P+C Schwick GmbH

Address
Bergisch Born 87A, 42897 Remscheid, NRW, Germany

E-Mail
info@schwick.de

Phone
+492191598280

Safety Instructions

⚠️ Safety and Warning Instructions for Measurement and Testing Equipment

Before using our measurement and testing equipment (such as multimeters, current/ground fault clamps, voltage testers, laser and environmental measuring devices, laboratory power supplies, oscilloscopes, and testing and inspection tools), please be sure to observe the following warnings:

Electrical Safety & Voltage Hazards (Danger to Life)

  • Risk of electric shock: Check devices and test leads for damage (e.g., cracks in the insulation, exposed wires) before each use. Damaged devices or cables must never be used!
  • Measurement categories (CAT): Pay attention to the permissible overvoltage category (e.g., CAT III 600V, CAT IV 300V). Never use the devices in mains circuits that exceed the specified category or the maximum rated voltage/current.
  • Voltage-free condition: Perform resistance, continuity, diode, or capacitance measurements exclusively on voltage-free circuits. Capacitors must be discharged before measurement.
  • Fuses: Replace defective fuses in multimeters exclusively with the exact same type (usually high-resistance ceramic fuses with the same voltage and current specifications). Never bypass them!
  • Grounding & Lab Power Supplies: Operate mains-powered test equipment (e.g., oscilloscopes, lab power supplies, function generators) only from properly grounded outlets. Incorrect voltage or current settings on laboratory power supplies can destroy connected components, which can lead to fire or explosion (e.g., of electrolytic capacitors).

Laser Radiation & Optical Hazards

  • Eye injuries: Many devices (laser rangefinders, infrared thermometers, tachometers) use aiming lasers. Never look directly into the laser beam and do not point it at people or animals.
  • Reflections: Caution around reflective surfaces! The laser beam can be deflected and unintentionally strike the eye.
  • Risk of glare: Borescopes and inspection cameras often have very bright LEDs. Do not look directly into the light source.

Heat, fire hazard & environmental conditions

  • Risk of burns: When using thermal imaging cameras or contact thermometers to measure hot components (e.g., in industrial settings or on engines), there is a risk of accidentally touching hot surfaces. The measuring device itself does not protect against the heat of the test object.
  • Wetness & Moisture: Never use electrical measuring instruments in wet, damp, or extremely condensing environments unless they explicitly have a corresponding IP protection rating. Moisture inside the device can lead to fatal short circuits.
  • Explosion hazard: The devices are generally not EX-protected. Do not use them in environments containing explosive gases, vapors, or dust.

Mechanical hazards & handling

  • Rotating machine parts: When using tachometers, anemometers, or stroboscopes on running machines, there is an extreme risk of entanglement. Maintain a safe distance and do not wear loose clothing, have your hair down, or wear dangling jewelry. Ensure that test leads do not come into contact with moving parts.
  • Falls & Equipment Damage: A dropped measuring device (e.g., multimeter, insulation tester) may be internally damaged, which means protection against electric shock is no longer guaranteed. If in doubt, have the device tested at 230V before using it again.
  • Magnetic fields: Some devices or mounts contain strong magnets. Keep them away from pacemakers, magnetic data storage devices, and sensitive electronics.

General Information & Health

  • Technical expertise: Work on electrical systems (especially those operating at 50V AC / 120V DC or higher) must only be performed by appropriately trained professionals.
  • Batteries: Remove batteries/rechargeable batteries if the device is not used for an extended period of time to prevent damage and burns caused by leaking battery acid.
  • Children: These high-precision test and measurement devices are not toys. Keep them out of the reach of children.